H.264 megapixel ip d/n poe box camera (dc 12v / poe) (19 pages)
Summary of Contents for ACTi CAM-5100
Page 1
Full D1 IP Camera CAM-5100 User’s Manual...
Page 2
CAM-5100 Feb, 2005 This document is copyrighted, 2005, by ACTi Corporation. All rights are reserved. ACTi Corporation reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of the original manufacturer.
Build-in LAN and WAN (Low Latency PPPoE Supported) Ports CAM-5100 provides two RJ-45 connectors. One is WAN and the other is LAN. The WAN port is to be connected to the internet, while LAN port is connecting to the local network.
Page 6
Bundle Powerful Surveillance Software To extend the capabilities of CAM-5100, a powerful surveillance program is included in the package and totally free to use. Users can easily utilize the existing PC to be a digital video recorder or multiplexer. Schedule or one-click recording keep every important moment in the local hard disk, reliable motion detection and instant warning make you sharp for every conditions.
Page 8
RS-485 The RJ45 connector for RS-485 serial port as a communication to external device. Pin assignment please reference 1.3.1 in page 1-8.
Page 9
Reset Button Switch off the CAM-5100 by disconnecting the power cable Release the screw and replace the Side_Plate Using a suitable pointed object, press and continue to hold the Reset Button depressed. While continuing to hold the Reset Button depressed,...
Page 10
Auto IRIS Output Auto IRIS Control Video / DC (Switchable) Video DC Level Adjustment Auto Electronic Shutter AES OnL 1/50 (60) sec. ~ 1/100,000 sec; AES Off: 1/50 (60) sec. Back Light Compensation On / Off (Switchable) Flickerless On / Off (Switchable) Automatic Gain Control On / Off (Switchable) Auto White Balance...
Please follow the following steps to configure your CAM-5100 before you install and running ACTi bundled software application. 2.1.1 Make sure network environment Default IP of CAM-5100 is 192.168.1.1. Please make sure CAM-5100 and your PC are in the same network segment before running the installation. Please set the number from 2 to 254.
The Ethernet cable and power cable are necessary for previewing function.Make sure all cables are correctly and firmly connected. 1. Connect an analog monitor to CAM-5100 Video Out (BNC connector) 2. Connect the power adaptor to CAM-5100 3. Connect CAM-5100 LAN port to an Ethernet hub (RJ45 connectors) 4.
2.2 Web Server Configuration Whenever you want to configure the CAM-5100, you can access the Configuration Utility by opening the web-browser and typing in the IP Address of the CAM-5100. The CAM-5100 default IP Address is 192.168.1.1 Please open the internet browser as 192.168.1.1...
2.2.1 Login Please login with specific Account and Password Account : Type Admin as the default account name. 2. Password : Type 123456 as the default password. 3. Language : Choose the language of Web Configurator. The default setting is English. Value Description English...
Please register your client information through ACTi CD before viewing live video NOTE: In your Client PC, please make sure the setting of Network Connections Type is set to Auto Negotation, since CAM-5100 follows MII standard. Otherwise, you might not see the live video.
Page 17
Video Display: Viewing live video Quit: Quit the Video Display function...
2.2.3 Host Setting Please config the LAN setting of this section 1. Host Name : Enter the domain name for CAM-5100 2. Language : Language setting for Web Configurator after Save Reboot. Default setting is English. Value Description English Tradition Chinese...
Page 19
10 Mbps / Full Duplex 10 Mbps / Half Duplex NOTE: Check with your MIS department, if Client PC and CAM-5100 are setting in different VLANs, please connect to WAN port. NOTE: In your Client PC, please make sure the setting of Network Connections Type is set to Auto Negotation, since CAM-5100 follows MII standard.
2.2.4 WAN Setting Please config the WAN setting of this section...
Page 21
: Click this button to apply the setting of this section : Click this button to reset NOTE: Check with your MIS department, if Client PC and CAM-5100 are setting in different VLANs, please connect to WAN port. NOTE: In your Client PC, please make sure the setting of Network Connections Type is set to Auto Negotation, since CAM-5100 follows MII standard.
2.2.5 Date Setting Please set the date and time by SNTP/NTP server or by manually 1. SNTP/NTP Server : Set automatically sync mode for date & time via network. 2. IP Address : The IP address of the SNTP/NTP server. 3.
2.2.6 Video Setting Please config the settings to meet your video input/output requirements 1. Camera Name : Set the specific ID for this Video Server / IP Cam 2. LAN Streaming : Set Multicast or TCP mode for LAN, Default is Multicast. 3.
Page 24
6. Resolution : Default is NTSC 720*480. Value Description N720x480 N352x240 N160x112 7. Bitrate: Default is 1.2Mbps Value Description 28 Kbps 56 Kbps 128 Kbps 256 Kbps 384 Kbps 500 Kbps 750 Kbps 1 Mbps 1.2 Mbps 1.5 Mbps 8. TOS : Add TOS flag to in order to support QoS in RTP/RTCP package default set Disabled.
2.2.7 Video Adjustment This section allows you to fine tune the image quality and preview the video 1. Video Preview Window 2. Hue Adjustment 3. Brightness Adjustment 4. Saturation Adjustment Contrast Adjustment : Click this button to apply the setting of this section : Click this button to reset Save Reboot is necessary to execute for keeping this configuration NOTE:...
2.2.8 User Account Management Please set the users account and password in this section 1. Root : Default Account name is Admin, Password is 123456. 2. USER 1 ~USER 10 : 10 users Account & Password could be defined. : Click this button to apply the setting of this section. : Click this button to reset.
2.2.9 Logo Setting Please config your favorite layout in this section 1. Main window header, please insert an image file (bmp, jpg, gif). Resolution is 776x81, and size < 12000 bytes 2. Main menu bar color 3. Sub window header bar color 4.
Page 28
Save Reboot is necessary to execute for keeping this configuration NOTE: after reboot next time. NOTE: Before re-connect to CAM-5100, please run Tools -> Internet Options -> General, and execute “Delete Cookies” and “Delete Files” in Temporary Internet files to clean temp files of IE Browser. 2-17...
2.2.10 System Info This section shows system information and system log System Information : View system information. WAN Status : View WAN status. System Log : View network status, system events and gather information about hardware problems. 2-18...
You can update the Firmware Image version of your device by downloading the latest firmware released from the http://www.acti.com to your hard drive or to a local directory, and then using the WebUI to load the new release onto your Hardware device.
2.2.13 Factory Default This section allows you to load factory default settings 1. Click to get back to factory default : Click this button to reset Save Reboot is necessary to execute for keeping this configuration NOTE: after reboot next time. 2-21...
2.2.14 Save Reboot When you finish all settings, please click Save Reboot and wait about 30 seconds for system save and reboot, until the LAN/WAN yellow LED is flashing, means boot up successful and start streaming. 2-22...