CB1200-I Pellet Insert
I. Removing Metal Floor of Factory-Built
Firebox
The fi rebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory-built
fi rebox in order to gain minimum insert opening require-
ments.
Any smoke shelves, shields and baffl es may be removed
from a factory-built fi rebox if attached with mechanical fas-
teners.
The metal fl oor of the factory-built fi rebox may be removed
to facilitate the installation of the insert only when a 1 inch
(25mm) airspace is provided between the insert and the
fl oor of outer wrap.
If the fl oor is made of thin metal, we recommend using a
Quarda-Fire fl oor protector, Part 811-0730, which is avail-
able through your dealer.
Starter hole
Mark area of
floor to cut
Figure 12.1. Measure and mark the metal fl oor for cutting.
With a drill, make a starter hole in each corner.
Figure 12.2. Using a saws-all, cut out the fl oor.
Keep sharp edge of
metal floor away from
power cord
Figure 12.3. Place the insert into the factory-built fi rebox.
Ensure that the power cord can not be damaged by the sharp
metal edge. You may need to cut out a notch to accommo-
date the cord.
Page 12
J. Altering the Factory-Built Fireplace
• The fireplace must not be altered, except for the
exceptions listed below. Do not removal the bricks and
mortar from the existing fi replace.
The following modifi cations are premissible:
• Removal of damper or locked in open position
• Removal of smoke shelf or baffl e
• Removal of ember catches
• Removel of fi re grate
• Removal of view screen/curtain
• Removal of doors
• External trim pieces which do not affect the operation
of the fi replace may be removed providing they can be
stored on or within the fi replace for reassembly if the insert
is removed.
• The permanent metal warning label provided must be
attached to the back of the fi replace, with screws or
nails, stating that the fi replace may have been altered to
accommodate the insert, and must be returned to original
condition for use as a conventional fi replace. Figure
12.4.
• If the hearth extension is lower than the fi replace opening,
the portion of the insert extending onto the hearth must
be supported.
• Manufacturer designed adjustable support kit can be
ordered from your dealer.
• Final approval of this installation type is contingent upon
the authority having jurisdiction.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation into
fi replaces without a permit will void the listing
WARNING! Risk of Fire!
Follow venting manufacturer's clearances and instructions
when installing venting system.
NOTICE: In Canada when using a factory-built chim-
ney it must be safety listed, Type UL103 HT (2100
o
[1149
C] CLASS "A" or conforming to CAN/ULC-
S629M, STANDARD FOR 650
CHIMNEYS.
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING

FIREPLACE.

Figure 12.4
7014-188
o
F)
o
C FACTORY-BUILT
250-2061
250-2061
September 16, 2009
R