Advance Planning; Electrical Supply - GE Monogram ZV750 Installation Instructions Manual

36" vent hood
Hide thumbs Also See for Monogram ZV750:
Table of Contents

Advertisement

Advance
Using Duct Cover Accessories
• A duct cover accessory may be required for
Planning
your hood installation height. Refer to this
chart to determine the need for the ZX10SY
accessory.
ZV750SY Duct Cover Dimensions
Hood and
Accessory
ZX750SY
ZX10SY
Ductwork
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the
outdoors.
• Use the shortest and straightest duct route
possible. For satisfactory performance, duct run
should not exceed 100 feet equivalent length for
any duct configurations.
• Refer to "Duct Fittings" chart to compute the
maximum permissable length for duct runs to the
outdoors.
• Install a wall cap with damper or roof cap at the
exterior opening.
Electrical
Supply
Do not use an extension cord or adapter
plug with this appliance. Follow National
Electrical Code or prevailing local codes
and ordinances.

Electrical supply

This vent hood must be supplied with 120V,
60Hz., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20
ampere circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the
above requirements, call a licensed electrician
before proceeding.
• Route wiring as close to the installation
location as possible, in the ceiling or soffit.
4
A
B
22-13/16"
18-7/8"
34-1/4"
Warning, for
Personal Safety:
Remove house fuse or open
circuit breaker before beginning
installation.
Design Information
36" Vent Hood
ZV750SY Installation Heights
Actual
Ceiling
Height
7' 11"
8' 0"
8' 1"
9-1/4"
8' 2"
8' 3"
B
8' 4"
8' 5"
A
8' 6"
8' 7"
8' 8"
11-7/8"
8' 9"
8' 10"
8' 11"
9' 0"
9' 1"
9' 2"
9' 3"
9' 4"
9' 5"
9' 6"
9' 7"
9' 8"
9' 9"
9' 10"
9' 11"
10' 0"
* Based on 36" countertop height.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding Instruction
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the
hood.
WARNING
Warning: The improper
connection of the equipment-
grounding conductor can result in
a risk of electric shock. Check with
a qualified electrician or service
representative if you are in doubt whether
the appliance is properly grounded.
* Possible Hood
Duct Cover
Installation Height
24-1/2"
25-1/2"
25-1/2" to 26-1/2"
25-1/2" to 27-1/2"
25-1/2" to 28-1/2"
25-1/2" to 29-1/2"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"