4.6 Fan Maintenance & Care
Clean the fan air inlet louvers and squirrel cage impeller regularly. The fan should be kept clean and
dust free. Life of the fan will be shortened if operated in a dust filled environment, or if the fan is
overheated by restricting air supply. Stalling the rotor, or over firing the insert with the fan turned off
will also damage the fan. The fan must not be overheated. Do not disassemble the fan.
OR TAMPERING WITH THE FAN WILL VOID THE WARRANTY".
4.7 Removal instructions
To remove your insert :
Remove the coil handle attached to the air intake control
Remove the four screws attaching the faceplate to the insert
Remove the faceplate by pulling on it
Unclip the ash pan
Unclip the blower assembly
Remove the three screws securing the pipe connector
FACEPLATE
ASH PAN
BLOWER
ASSEMBLY
29
"ALTERING
COIL
HANDLE
AIR INTAKE
CONTROL