3.2

Terminal assignment Ex i

Terminal Interface
Scanner connection
(optional)
X1
Hand-held scanner
X2
Supply
X3
Supply
PS/2 interface for input devices
X4
PS2
X5
PS2
X6
PS2
X7
PS2
X8
PS2
X9
PS2
3.3

Electrical installation

3.3.1

EMC notes

This device is class A equipment and may cause interference in domestic
electrical equipment. If this occurs, the installer of the device may be required to
implement appropriate counter measures.
All connection cables must be shielded. This applies both to data lines and to other cables.
The data cables must be twisted in pairs. Example: 2 x 2 x 0.75 mm² LIYCY TP.
If possible, cables for power supply and data must be laid separately.
E_BMS790_POLARIS_PanelPC_19+15_Rev1.doc
Colour
WH/BN
GN/YE
PK
GR
BL
RD
User manual for POLARIS Panel PC 19.1" and 15"
Signal
Remarks
+UB
Supply voltage +5 V
RxD-I
Data input RS232 signal
GND
Mass connected to protective earth
VCC
Supply voltage
GND
Mass connected to protective earth
KB_CLK
Keyboard clock signal
KB_DATA
Keyboard data signal
MS_CLK
Mouse
MS_DATA
Mouse
Revision 1 / Status: January, 3
, 2006
Technical data subject to change
rd
Page 17 of 46
clock signal
data signal