Specifications - Bryant EVOLUTION 987MA Product Data

Modulating 4-way multipose, variable speed condensing gas furnace, series a
Table of Contents

Advertisement

Heating Capacity and Efficiency
Maximum
Input
Heat
Intermediate
Heat
Minimum
Heat
Maximum
Output
Heat
Intermediate
Heat
Minimum
Heat
Efficiency
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device

SPECIFICATIONS

42060
(BTUH)
60,000
(BTUH)
39,000
(BTUH)
24,000
(BTUH)
59,000
(BTUH)
38,000
(BTUH)
24,000
AFUE % (ICS)
97.0
35 - 65
Maximum Heat
(19 - 36)
50 - 80
Intermediate Heat
(28 - 44)
35 - 65
Minimum Heat
(19 - 36)
42060
Heating
0.12
Cooling
0.5
Maximum Heat
1075
Intermediate Heat
530
Minimum Heat
415
Cooling
1335
CFM/ton
3
CFM/ton
3.5
1/2
7.7
in.
11 x 8
KGAWF1306UFR KGAWF1406UFR KGAWF1306UFR
42060
Volts-Hertz-Phase
Min-Max
Amps
9.7
Amps
12.7
AWG
14
Feet
29
(M)
(8.8)
Amps
15
Heating
Cooling
42060
1/2" - NPT
3
Manufacturer
60060
42080
60,600
80,000
80,000
39,000
52,000
52,000
24,000
32,000
32,000
60,000
78,000
78,000
39,000
51,000
51,000
24,000
31,000
31,000
98.3
97.0
35 - 65
40 - 70
40 - 70
(19 - 36)
(22 - 39)
(22 - 39)
40 - 70
50 - 80
50 - 80
(22 - 39)
(28 - 44)
(28 - 44)
25 - 55
35 - 65
35 - 65
(14-31)
(19 - 36)
(19 - 36)
60060
42080
0.12
0.15
0.5
0.5
1080
1500
690
750
555
620
1905
1375
4.5
3.5
5.5
4
Electronically Commutated Motor (ECM)
1
1/2
12.8
7.7
300 - 1300
Variable (Communicating)
11 x 10
11 x 8
11 x 10
Factory Supplied Media Cabinet
Field Supplied Filter
60060
42080
115-60-1
104 -127
14.8
9.7
19.1
12.7
12
14
30
29
(9.1)
(8.8)
20
15
40VA
27.9 VA
34.6 VA
60060
42080
3
4
White Rogers
4.5
13.6
KGANP5201VSP
KGAPN4401VSP
not approved for MH use
Silicon Nitride
3
60080
66100
66120
100,000
120,000
65,000
78,000
40,000
48,000
98,000
117,000
64,000
76,000
39,000
47,000
97.0
97.0
97.0
45 - 75
45 - 75
(25 - 42)
(25 - 42)
50 - 80
50 - 80
(28 - 44)
(28 - 44)
35 - 65
35 - 65
(19 - 36)
(19 - 36)
60080
66100
66120
0.15
0.20
0.20
0.5
0.5
0.5
1345
1575
1820
795
955
1100
595
745
900
1945
2160
2185
4.5
5.5
5.5
5.5
6
6
1
1
1
12.8
12.8
12.8
11 x 10
11 x 11
KGAWF1406UFR
KGAWF1506UFR
60080
66100
66120
14.8
14.8
14.8
19.1
19.1
19.1
12
12
12
30
30
30
(9.1)
(9.1)
(9.1)
20
20
20
60080
66100
66120
4
5
6

Hide quick links:

Advertisement