Bryant 926TA Product Data

Bryant 926TA Product Data

Preferred two-stage 4-way multipoise, variable speed condensing gas furnace, series a

Advertisement

926TA
PREFERREDt TWO- -STAGE
4- -WAY MULTIPOISE, VARIABLE SPEED
CONDENSING GAS FURNACE, SERIES A
The 926TA Multipoise Variable- -Speed Condensing Gas Furnace
features the two- -stage Preferredt Series System. The Perfect
HeatR technology two- -stage gas valve is at the heart of the
comfort provided by this furnace, along with the variable- -speed
ECM blower motor, and two- -speed inducer motor. With an
Annual Fuel Utilization Efficiency (AFUE) up to 96.5%, the
Preferredt Series two- -stage gas furnace provides exceptional
savings as well when compared to standard gas furnaces. This
Preferredt Series Gas Furnace also features 4- -way multipoise
installation flexibility, and is available in eight model sizes. The
926TA can be vented for direct vent/two- -pipe, ventilated
combustion air, or single- -pipe applications.
California Air Quality Management District emission requirements.
All sizes are design certified in Canada.
STANDARD FEATURES
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less
Product Data
cabinet airflow leakage.
S Quiet operation. Compare for yourself at HVACpartners.com.
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Silicon Nitride Perfect Light Hot Surface Igniter.
S SmartEvap technology helps control humidity levels in the
home when used with a compatible humidity control system.
S FanOn Plus technology allows control of continuous fan speed
from a compatible thermostat.
S 4- -way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through- -
the- -cabinet downflow venting capability.
S Full- -featured variable- -speed blower motor, two- -speed inducer
motor, and two- -stage gas valve.
S Self- -diagnostics.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized- -steel primary heat exchanger.
A11264
S Stainless- -steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory- -configured ready for upflow applications.
S Fully- -insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
All units meet
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1- -in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
Use of the AHRI Certified
manufacturer's participation in the program. For
verification of certification for individual products,
CERTIFIED
go to www.ahridirectory.org.
1
Mark indicates a
TM
Always Ask For

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 926TA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bryant 926TA

  • Page 1 S Installation flexibility: sidewall or vertical vent. installation flexibility, and is available in eight model sizes. The 926TA can be vented for direct vent/two- -pipe, ventilated S Residential installations may be eligible for consumer financing combustion air, or single- -pipe applications.
  • Page 2: Features And Benefits

    Power Heatt Igniter — Bryant’s unique SiN igniter is not only operation. physically robust but it is also electrically robust. It is capable of Monoport Burners —...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Example of a Model Number 1 - 2 6 - 7 8 - 10 12 - 13 Family/Tier Base Eff. Major Series Htg. Stages Htg. Cap. Motor Width Clg. Cap. Voltage Minor Series Features 91 - Legacy 0 - +90 AFUE 2 - +92 AFUE 92 - Preferred...
  • Page 4: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 30040 36040 36060 42060 48080 60080 60100 66120 High Heat (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000 Input Low Heat (BTUH) 26,000 26,000 39,000 39,000 52,000 52,000 65,000 78,000 High Heat (BTUH) 39,000 39,000 58,000 58,000...
  • Page 5 FILXXCAR0020 Use with FILCABXL ---1020 Cartridge Media Filter - 24” (610 mm) FILXXCAR0024 Use with FILCABXL ---1024 Bryant Perfect Air Purifier - 16x25 (406x635 mm) GAPAAXBB1625-A08 Up to 1600 CFM Bryant Perfect Air Purifier - 20x25 (508x635 mm) GAPAAXBB2025-A08 Up to 2000 CFM Bryant Perfect Air Purifier Repl.
  • Page 6 AIR DELIVERY - - CFM (SW1-5 and SW2---2 set to OFF, except as indicated. See notes 1 and 2) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 1.030 30040 Clg Default: 1125 1080 1020 note 8 Cooling (SW2) 1125 1080...
  • Page 7 AIR DELIVERY - - CFM (CONTINUED) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 42060 Clg Default: 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 See note 4 See note 4 Cooling (SW2) 1160 1120 1090 1045...
  • Page 8 AIR DELIVERY - - CFM (CONTINUED) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 60100 Clg Default: 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 1015 See note 4 1080 See note 4 1155 1080 1020 Cooling (SW2)
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 1 –...
  • Page 10: Venting System Length Calculations

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 11 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 3 –...
  • Page 12 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) No Insulation 3/8-in. (9.5 mm) 1/2-in. (12.7 mm) Two Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace High Length in Temp ° F (° C) Heat Input Ft.
  • Page 13: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 14 Bryant cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 15: Typical Wiring Schematic

    OPTIONAL MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 16: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 926TA SHIP WT. FURNACE SIZE LB (KG) CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 30040 121.0 (55.0) 14--- 3/16 (361) 12--- 1/2 (319) 12--- 9/16 (322) 7--- 1/8 (181) 36040 130.5 (59.2) 36060 131.5 (59.6)
  • Page 17: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 18 Catalog No. PDS926TA ---03 E2014 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 09/14 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents

Save PDF