Technical Specifications; Table 6: Technical Specifications - Bryant OVM098 Installation Instructions Manual

Multipoise oil furnace
Hide thumbs Also See for OVM098:
Table of Contents

Advertisement

Available languages

Available languages

6 TECHNICAL SPECIFICATIONS

098 Series, multi-position models
RATING AND PERFORMANCE
Firing rate(USGPH)*
Input (BTU/h)*
Maximum Heating capacity, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; AFG MODEL (Chimney)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
Low firing rate baffle
Pump pressure (PSIG)*
Head/Air setting (damper/band)
AFUE % (From CSA B212 standard and Canadian regulation)***
AFUE % ( From ASHRAE 103 standard and US regulation)***
BECKETT BURNER; NX MODEL (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
Low firing rate baffle
Pump pressure (PSIG)*
Combustion air adjustment
AFUE % (From CSA B212 standard and Canadian regulation)***
AFUE % (From ASHRAE 103 standard and US regulation)***
RIELLO BURNER; 40-F3 MODEL (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)**
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)***
AFUE % (From ASHRAE 103 standard and US regulation)***
RIELLO BURNER; 40-BF3 MODEL (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)**
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)***
AFUE % (From ASHRAE 103 standard and US regulation)***
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available: Heating / Cooling (VA)
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
Heating blower speed at 0.50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size (depth x height x thickness)
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
Table 6 – Technical specifications
* INPUT AND OUTPUT ADJUSTMENT :
- Pump pressure can be adjusted to maintan proper firing rate
- Increase pump pressure if flue gases' temperature is under 400°F
- Adjust the total flue gas temperature between 400°F and 575 °F (330°and 505°F net approx.)
- Adjust fan speed for air temperature rise to be in specified range
** Default installed Nozzle in bold characters.
** AFUE value established after minimum 20 hours of operation.
UNITS WITH 1/3 HP PSC MOTOR
0.50
0.60
70,000
84,000
59,000
70,000
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
AFG70MQSS
1 3/4"
2 Slots - L2 head
0.40 - 60A
0.50 - 60A
Yes (5580)
Yes (5580)
175
150
4/0
8/0
85.6%
85.6%
85.2%
85.1%
NX56LQ
1 3/4"
6 Slots - LQ head
0.40 - 60W
0.50 - 60W
Yes (32229)
Yes (32229)
155
145
2.0
2.75
86.7%
85.7%
86.1%
85.4%
F3 WITH AIR INLET DAMPER
2 3/4"
0.40 - 70A
0.50 - 70A
155
145
0 / 1.5
0 / 2.5
87.0%
86.3%
86.4%
85.9%
BF3
2 3/4"
0.40 - 70A
0.50 - 70A
155
145
0 / 3.25
0 / 4
85.6%
85.3%
85.1%
85.0%
115 - 60 - 1
12.2
13.7
15
40
40 / 30
MED-LOW
MED-HIGH
MED-LOW
MED-HIGH
1/3 HP / 4 speeds
10" x 8"
16 7/8" x 20 1/8" x 40 3/4"
16" x 19"
19" x 19"
20" x 20" x 1"
125 / 57
2.5
‡=
13
UNITS WITH 1/2 HP ECM MOTOR
0.70
0.50
98,000
70,000
81,000
59,000
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
AFG70MQSS
2 Slots - L2 head
0.60 - 60B
0.40 - 60A
No
Yes (5580)
140
175
5/0
4/0
‡ 85.6%
84.3%
83.9%
‡ 85.2%
6 Slots - LQ head
0.60 - 60W
0.40 - 60W
No
Yes (32229)
135
155
2.5
2.0
85.0%
‡ 86.7%
84.5%
‡ 86.1%
F3 WITH AIR INLET DAMPER
0.60 - 70A
0.40 - 70A
135
155
1 / 3.5
0 / 1.5
84.9%
‡ 87.0%
84.5%
‡ 86.4%
0.60 - 70A
0.40 - 70A
135
155
1 / 5.25
0 / 3.25
84.0%
‡ 85.6%
83.3%
‡ 85.1%
115 - 60 - 1
HIGH
HIGH
See the ECM air flow table
1/2 HP / ECM (with inductor)
16 7/8" x 20 1/8" x 40 3/4"
20" x 20" x 1"
0.60
84,000
70,000
1 3/4"
0.50 - 60A
Yes (5580)
150
8/0
‡ 85.6%
‡ 85.1%
NX56LQ
1 3/4"
0.50 - 60W
Yes (32229)
145
2.75
‡ 85.7%
‡ 85.4%
2 3/4"
0.50 - 70A
145
0 / 2.5
‡ 86.3%
‡ 85.9%
BF3
2 3/4"
0.50 - 70A
145
0 / 4
‡ 85.3%
‡ 85.0%
10.3
12.2
15
40
40 / 30
10" x 8"
16" x 19"
19" x 19"
125 / 57
3.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obm098098 series

Table of Contents