Bryant PLUS 95S Installation Instructions Manual (63 pages)
SERIES A DIRECT-VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE WITH PERFECT SENSE PERFECT HUMIDITY
Brand:
Bryant
| Category:
Furnace
| Size: 4.2 MB
Table of Contents
Installation Instructions
1
Important Information
2
Table of Contents
3
Safety Considerations
3
Dimensional Drawing
4
Installer Packet Contents
5
Loose Parts Bag Contents
5
Installation
6
Minimum Inches Clearance to Combustible Construction
6
Combustion
7
Codes and Standards
7
Electrostatic Discharge (Esd) Precautions
7
Introduction
7
Upflow Application
8
Condensate Trap Tubing
8
Applications
8
Condensate Trap (Alternate Upflow Orientation)
9
Upper Inducer Housing Drain Connection
10
Upper Collector Box Drain Connection
10
Pressure Switch Tubing
10
Trap Location
10
Downflow Applications
11
Condensate Trap Location
11
Horizontal Left (Supply - Air Discharge) Applications
12
Horizontal Left Tube Configuration
12
Attic Location and Working Platform
13
Construct a Working Platform
14
Horizontal Right (Supply - Air Discharge) Applications
15
Carbon Monoxide Poisoning Hazard
15
Location
16
Furnace Location Relative to Cooling Equipment
17
Hazardous Locations
17
Installation in Horizontal Applications
18
Installation in Upflow or Downflow Applications
18
Leveling Legs
18
Duct Flanges Diagram
19
Furnace, Plenum, and Coil Assembly or Coil Box Diagram
19
Furnace, Plenum, and Subbase Installed on a Combustible Floor
19
Crawlspace Horizontal Application for Direct Vent
20
Air Ducts
21
Ductwork Acoustical Treatment
21
Opening Dimensions
21
Supply Air Connections
21
Filter Arrangement
22
Return Air Connections
22
Bottom Closure Panel
23
Gas Piping
23
Casing Pipe Grommets
24
Removing Bottom Closure Panel
24
Typical Gas Pipe Arrangement
24
115V Wiring
25
Electrical Connections
25
Maximum Capacity of Pipe
25
Disconnect Switch and Furnace
26
Electrical Data
26
Heating and Cooling Application Wiring Diagram
26
24V Wiring
27
Electronic Air Cleaner (Eac)/Humidifier (HUM)
27
J-Box Relocation
27
Removal of Existing Furnaces from Common Vent Systems
27
Air for Combustion and Ventilation
28
Combustion - Air and Vent Pipe Systems
28
Direct Vent / 2-Pipe System
28
Ventilated Combustion Air Option Materials
28
Approved Combustion-Air and Vent Pipe, Fitting and Cement Materials
29
Combustion-Air and Vent Pipe Diameter
29
Installation Guidelines for Combustion Air Pipe and Vent Pipe
29
Furnace Control
30
Direct Vent Termination Clearance
31
Ventilated Combustion Air Vent Termination Clearance
32
Combustion Air and Vent Termination for Direct Vent (2-Pipe) System
33
Vent Pipe Termination for Ventilated Combustion Air System
33
Combustion Air and Vent Pipe Connections
34
Combustion Air and Vent Pipe Transition Location/Elbow Configuration
34
Combustion Air Pipe Attachment
34
Attachment of Combustion Air Intake Housing Plug Fitting
35
Combustion Air Termination - Ventilated Combustion Air Option
35
Intake Housing Plug Fitting Drain
35
Combustion Air Termination - Direct Vent / 2-Pipe System
36
Vent Pipe
36
Attic Termination
37
Crawlspace Termination
37
Short Vent (5 to 8 Ft. / 1.5M to 2.4M) System
38
Concentric Vent / Combustion Air Termination Kit/2-Pipe System Only
39
Extended Exposed Sidewall Pipes
39
Two-Pipe Termination Kit (Direct Vent/2-Pipe System
39
Vent Termination
39
Maximum Allowable Exposed Vent Pipe Length with Insulation
40
Maximum Allowable Pipe Length
41
Condensate Drain
43
Multi-Venting and Vent Terminations
43
Vent Termination Kit for Direct Vent/2-Pipe System
43
Air Conditioning (A/C) Setup Switches
44
Continuous Fan (CF) Setup Switches
44
Setup Switches
44
Start- -Up, Adjustments, and Safety Check
44
Prime Condensate Trap with Water
45
Wiring Diagram
46
Inducer Housing Drain Tube
47
Filling Condensate Trap
47
Furnace Setup Switch Description
47
Purge Gas Lines
48
Single-Stage Thermostat and Step-Modulating Heating
48
Two-Stage Thermostat and Two-Stage Low / High Heating
49
Two-Stage Thermostat and Two-Stage Medium/High Heating
49
Switching from Low- to High-Heat
49
Switching from Medium- to High-Heat
49
Cooling Mode
50
Thermidistat Mode
50
Component Test
51
Heat Pump
51
Continuous Blower Speed Selection from Thermostat
51
Super Dehumidify Mode/Continuous Blower Mode
51
Adjustments
54
Set Gas Input Rate
54
Redundant Automatic Gas Valve
54
Burner Orifice
55
Orifice Size and Manifold Pressures for Gas Input Rate
56
Altitude Derate Multiplier for USA
58
Burner Flame
58
Set Temperature Rise
59
Set Thermostat Heat Anticipator
59
Gas Rate Cu Ft/Hr
59
Check Safety Controls
60
Check Primary Limit Control
60
Check Pressure Switches
60
Checklist
60
Advertisement
Bryant PLUS 95S Product Data (21 pages)
100 Series DELUXE 4-WAY MULTIPOISE VARIABLE-SPEED MULTI-STAGE CONDENSING Input Rates: 60,000 thru 120,000 Btuh
Brand:
Bryant
| Category:
Furnace
| Size: 1.63 MB
Table of Contents
Furnace Components
3
Physical Data
8
Performance Data
8
Operating Mode
9
Condensate Trap
11
Electrical Data
14
Typical Wiring Schematic
14
Clearance to Combustibles
17
Typical Installations
18
Guide Specifications
20
Operating Characteristics
20
Electrical Requirements
20
Bryant PLUS 95S Owner's Manual (14 pages)
DIRECT VENT 4-WAY MULTIPOISE MODULATING CONDENSING GAS FURNACE WITH PERFECT SENSE PERFECT HUMIDITY
Brand:
Bryant
| Category:
Furnace
| Size: 0.61 MB
Table of Contents
Table of Contents
2
Welcome to a New Generation of Comfort
2
Components View
3
Furnace Components
3
Safety Considerations
4
Before Starting Your Furnace
4
Starting and Shutting down Your Furnace
5
Steps for Starting Your Furnace
5
Shutting down Your Furnace
7
Performing Routine Maintenance
7
Filtering out Trouble
7
Combustion Area and Vent System
10
Heading South for the Winter
11
Troubleshooting
13
A Check- -Up Checklist
13
Before You Request a Service Call
13
Installation Data
14
Advertisement
Advertisement
Related Products
Bryant PLUS 90X 353AAV
Bryant PLUS 95S 355CAV
Bryant PO8UAA
Bryant PG96VTA
Bryant PURON PLUS 598B
Bryant ZONE PERFECT PLUS A96447
Bryant DURAPAC PLUS 581B
Bryant DURAPAC PLUS SERIES 542J
Bryant DURAPAC PLUS 581A
Bryant DuraPac Plus 549B
Bryant Categories
Furnace
Air Conditioner
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL