Table 6: Technical Specifications - Bryant OBM098 Installation Instructions Manual

Multipoise oil furnace input capacities 70,000 ---98,000
Hide thumbs Also See for OBM098:
Table of Contents

Advertisement

Available languages

Available languages

MULTI POSITIONS MODELS - SERIES 098
RATING AND PERFORMANCE
Firing rate (USGPH)*
Input (BTU/h)*
Maximum Heating capacity, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c.)
Overfire pressure with direct vent (inch of w.c.)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Head/Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-BF3 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available
Heating (VA)
Cooling (VA)
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
Heating blower speed at 0.50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size (depth x hieght x thickness)
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5 SP
* INPUT & OUTPUT ADJUSTMENT
Pump pressure can be adjusted to maintain proper firing rate.
Increase pump pressure if flue gases temperature is under 400˚F
Adjust the total flue gas temperature between 400˚F and 575˚F (330˚F and 505˚F net approximately)
Adjust fan speed for air temperature rise of 55˚ to 85˚F.
** AFUE value established after minimum 20 hours of operation.

Table 6: Technical specifications

UNITS WITH 1/3 HP PSC MOTOR
0,50
0,60
70 000
84 000
59 200
70 400
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
NX56LQ
1 3/4''
6 - Slot LQ head
0.40 - 60A
0.50 60A
155
145
0,5
1,5
85.0 ‡
84,2
85.0 ‡
83,9
F3 WITH AIR INLET DAMPER
2 3/4''
0.40 - 70A
0.50 - 70A
155
145
0 / 1.5
0 / 2.5
85.0 ‡
84,2
85.0 ‡
83,9
BF3
2 3/4''
0.40 - 70A
0.50 - 70A
155
145
0 / 3.25
0 / 4
85.0 ‡
84,2
85.0 ‡
83,9
115 - 60 - 1
12.2
13.7
15
40
40
30
MED-LOW
MED-HIGH
MED-LOW
MED-HIGH
1/3 HP / 4 speeds
10'' x 8''
16.875'' x 20 1/8'' x 40 3/4''
16'' x 19''
19'' x 19''
20'' x 20''
125 / 57
2,5
15
UNITS WITH 1/2 HP ECM MOTOR
0,70
0,50
0,60
98 000
70 000
84 000
80 800
59 200
70 400
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
NX56LQ
1 3/4''
6 - Slot LQ head
0.60 - 60A
0.40 - 60A
0.50 - 60A
135
155
145
2,5
0,5
1,5
81,9
85.0 ‡
84,2
85.0 ‡
81,9
83,9
F3 WITH AIR INLET DAMPER
2 3/4''
0.60 - 70A
0.40 - 70A
0.50 - 70A
135
155
145
1 / 3.5
0 / 1.5
0 / 2.5
81,9
85.0 ‡
84,2
85.0 ‡
81,9
83,9
BF3
2 3/4''
0.60 - 70A
0.40 - 70A
0.50 - 70A
135
155
145
1 / 5.25
0 / 3.25
0 / 4
81,9
85.0 ‡
84,2
85.0 ‡
81,9
83,9
115 - 60 - 1
10.3
12.2
15
40
40
30
HIGH
See the ECM air flow table
HIGH
1/2 HP / ECM
10'' x 8''
16.875'' x 20 1/8'' x 40 3/4''
16'' x 19''
19'' x 19''
20'' x 20''
125 / 57
3.0
‡ =
0.70
98 000
80 800
0.60 - 60A
135
2,5
81,9
81,9
0.60 - 70A
135
1 / 3.5
81,9
81,9
0.60 - 70A
135
1 / 5.25
81,9
81,9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ovm098

Table of Contents