WALL SWITCH INSTALLATION
Since. the. VDVF36TPNEA/TSTEA. series.
uses.a.4.VAC.current.supplied.from.a.trans-
former.mounted.on.the.ignition.module.and.is.
prewired.for.easy.connection.to.a.wall.switch.
(see. Figure. 34)..The. (V)DVF36TPNA/TSTA.
models.use.a.self.generated.millivolt.current.
that. allows. you. to. activate. the. gas. control.
valve.directly.without.the.use.of.normal.house-
hold.electricity.(see.Figure.35)..Both.versions.
are.supplied.with.a.wall.switch.kit.for.ready.
connection.and.mounting.
WARNING: Do not wire re-
mote wall switch to main power
supply (Standard 120v house-
hold current).
1. To remove louvers, simultaneously pull
both.top.end.spring.latches.towards.center.
of. appliance. until. they. are. disengaged.
from. locating. holes.. Repeat. for. bottom.
spring.latches.and.pull.louvers.outward..
Reverse.procedure.to.install.louvers.back.
onto.appliance.(see.Figure.36).
.. Connect.18.gauge.wires.from.wall.switch.
to. gas. control. valve. terminals. marked.
TH.and.TPTH.or.to.ignition.module.using.
pigtails.and.wire.nut.connectors.supplied.
with.appliance.
Route.4V.(Supplied).
Through.Electrical.Conduit.
Bushing
Electrode
Make.Connections.
with.Wirenuts.
(Supplied)
Transformer
Plug.10V.AC.
To.Receptacle
G
P.
N
V2
L1
IND
SI
SW
TS
D
Figure 34 - Wall Switch Wiring Diagram,
Electronic Units
56131H
FIREPLACE INSTALLATION
E
A
Wall.Switch.
(Supplied)
G
P.
N
V2
IND
SI
SW
L1
TS
V1
D
Ignition.
18.AWG.
Control.
Red.Wire
Module
V1
www.desatech.com
CAUTION: Due to high tem-
peratures, make sure wires are
not touching upper firebox.
16AI
E
A
Route.Millivolt.Wires.
(Supplied).Through.Gas.
Line.Conduit.Sleeve
Figure 35 - Wall Switch Wiring Diagram,
Note: If any of the original wire supplied must
be replaced, use type 18 AWG-105 degree C
(25 feet length maximum) or equivalent.
Figure 36 - Removing Louver
(Back.
ELECTRICAL HOOKUP FOR
View)
OPTIONAL bLOWER ACCESSORY
Before blower accessory can be operated,
appliance. outlet. box. must. be. properly. con-
nected.to.a.standard.10.VAC.power.source..
This.must.be.done.when.appliance.is.origi-
nally.installed..Refer.to.Wiring Diagrams.on.
page.33.
An.outlet.box.with.two.receptacles.has.been.
supplied.for.your.convenience.and.is.located.
on. the. lower. right. side. of. appliance. (see.
Figure 37, page 22). The variable speed
controller. is. mounted. on. a. magnetic. base.
and. may. be. positioned. anywhere. within. an.
accessible.distance.behind.louvered.opening.
(see.Figure.36).
To.
Thermopile
16AI
Millivolt Units
Glass
Locating.
Holes
Recommended.
Blower.Speed.
Control.Location
Spring.
Latch
Wall.Switch.
(Supplied)
(Back.
View)
1