PARTS LIST FOR VENTING KITS
AND COMpONENTS
DESA (5"/8") Pipe & Vent Kits
Number
Description
P58-6
6" Section Double Wall Pipe,
Galvanized
P58-12
12" Section Double Wall Pipe,
Galvanized
P58-24
24" Section Double Wall Pipe,
Galvanized
P58-36
36" Section Double Wall Pipe,
Galvanized
P58-48
48" Section Double Wall Pipe,
Galvanized
PA58-712 Adjustable 7"-12" Section Double
Wall Pipe, Galvanized
E58-45
45° Elbow, Galvanized
E58-90
90° Elbow, Galvanized
HTS-58
Horizontal Square Termination,
Galvanized
CHECK GAS TYPE
Use proper gas type for the fireplace unit you
are installing. If you have conflicting gas types,
do not install fireplace. See retailer where you
purchased the fireplace for proper fireplace
according to your gas type.
INSTALLING GAS pIpING TO
FIREpLACE LOCATION
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
CAUTION: For propane/LP
units, never connect fireplace di-
rectly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between
the fireplace and propane/LP
supply.
123129-01A
ventinG inStALLAtiOn
Continued

FirePLAce inStALLAtiOn

www.ironhaus.com or www.desatech.com
Number
Description
VT-58
Vertical Round Termination,
Galvanized
SC-58
Storm Collar, Galvanized
WF-58
Wall Firestop, Galvanized
RF-58-6
Roof Flashing - 0 to 6/12 Pitch,
Galvanized
RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,
Galvanized
VR-58
Vertical Restrictor, Galvanized
S-58
Vinyl Siding Standoff, Galva-
nized
WS-58
Wall Strap
CS-58
Cathedral Ceiling Support
FP-58
Firestop Plate
SF-58
Stucco Flashing - For use with
HTS-58
RF-58
Flat Roof Flashing
AK6-37
37" Outside Air Flex Vent Kit
AK6-75
75" Outside Air Flex Vent Kit
WARNING: For natural
gas, never connect fireplace to
private (non-utility) gas wells.
This gas is commonly known
as wellhead gas.
Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connec-
tor (if allowed by local codes)
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the CSA design-certified equipment shutoff
valve from your retailer.