(V)DVF36TSTEA-(A)
• Input Rating: 35,000/23,300 Btu/Hr
•. Fuel:.Natural.Gas
•. Manifold.Pressure:.3.5".W.C.
•. Minimum.Supply.Pressure:.4.5.W.C..**
•. Maximum.Supply.Pressure:.10.5".W.C..
• Orifice Size (0-4500 ft.): #34 DMS
30
OPERATION
ELECTRONIC SySTEM

SPECIFICATIONS

**For.purpose.of.input.adjustment.
www.desatech.com
Continued
Continued
(V)DVF36TPNPA-(A),
(V)DVF36TPNPEA-(A),
(V)DVF36TSTP-(A) AND
(V)DVF36TSTPEA-(A)
• Input Rating: 31,000/20,000 Btu/Hr
•. Fuel:.Propane/LP.Gas
•. Manifold.Pressure:.10".W.C.
•. Minimum.Supply.Pressure:.11.W.C..**
•. Maximum.Supply.Pressure:.13".W.C..
• Orifice Size (0-4500 ft.): #51 DMS
56131H