Desa VVF36 Owner's Operation And Installation Manual page 23

Peninsula models
Table of Contents

Advertisement

Optional.Fan.
Kit.Plug
Extension.
Cord
Gas.
Valve
16AI
E
A
To.Thermopoile
Figure 40 - Installing Remote Receiver
(SKYTECH Model)
1.Volt.
Battery
Pull.to.Remove.
Insulation.Tab
Figure 41 - Installing Battery in Hand-
Held Remote Control Unit (SKYTECH)
GAS LINE HOOK-UP
WARNING: Before you pro-
ceed, make sure your gas supply
is OFF.
WARNING: Gas line hookup
should be done by your gas
supplier or a qualified service
person.
An equipment shutoff valve has been included
in. the. appliance's. gas. supply. system.. You.
may.consider.installing.an.extra.gas.shutoff.
valve. outside. appliance's. enclosure. (check.
with.local.codes).where.it.can.be.accessed.
more.conveniently.with.a.key.through.a.wall.
as.shown.in.Figure.4.
Route.a.1/".NPT.black.iron.gas.line.towards.
appliance.coming.in.from.the.left..It.is.recom-
mended to route pipe between stand of firebox
and surround of fireplace (see Figure 43).
56131H
FIREPLACE INSTALLATION
Continued
Outlet.Box
Receiver
White
Red
Battery.
Cover
www.desatech.com
IMPORTANT:.The.appliance.and.its.individual.
shutoff.valve.must.be.disconnected.from.the.
gas.supply.piping.system.during.any.pressure.
testing. of. that. system. at. test. pressures. in.
excess.of.1/.psig..(3.5.kPa)..The.appliance.
must.be.isolated.from.the.gas.supply.piping.
system by closing its individual equipment
shutoff.valve.during.any.pressure.testing.of.
the.gas.supply.piping.system.at.test.pressures.
equal to or less than 1/2 psig. (3.5 kPa).
CAUTION: Do not kink flex-
ible gas line.
CAUTION: Compounds used
on threaded joints of gas piping
shall be resistant to the action
of Liquefied Petroleum (LP or
propane), and should be applied
lightly to ensure excess sealant
does not enter the gas line.
1.. Install.a.sediment.trap.between.incoming.
gas.line.and.gas.control.valve.(see.Figure.
43).. The. sediment. trap. should. extend.
down.center.of.pipe..Refer.to.your.local.
codes.
Key
Figure 42 - Typical Exterior Wall Gas
Shutoff Installation
Incoming.1/".Gas.
Line.Permitted.by.
Local.Codes
Sediment.
Trap.(Not.
Supplied)
3" Min.
Figure 43 - Sediment Trap
Shutoff.
Valve
Extension
3