Quadra-Fire SANTAFE-MBK Owner's Manual Installation And Operation page 41

Santa fe pellet stove
Hide thumbs Also See for SANTAFE-MBK:
Table of Contents

Advertisement

Santa Fe Pellet Stove
16. Thermostat
The appliance is designed to run on a 12 volt AC thermostat.
The heat anticipator should be set on the lowest setting
available.
17. Snap Disc #1 (Convection Blower) 110°F
Snap disc #1 is located on the right side of the appliance on
the bottom of the heat exchanger box. There are 2 purple
wires connected to it. This snap disc turns the convection
blower on and off as needed. Power is always present at
snap disc #1.
18. Snap Disc #2 (Fuel Delivery Interrupt) 250°F
Snap disc #2 is also located on the back side of the feed drop
tube. There are 2 orange wires connected to it. This snap disc
will turn off the feed system which will turn off the appliance
if an overfi re condition should occur or if the convection
blower should fail to operate. If this occurs the snap disc will
automatically reset itself.
Thermocouple
Heat Output
Green
Yellow
Red
Orange
White
Blue
Black
Black
Yellow
Red
Purple
Gray
Blue
Black
Black
Igniter
Figure 41.1
September 3, 2009
Thermostat
Block
Switch
Call
Reset
Light
Button
19. Snap Disc #3 (Back Burn Protector) 250°F
Snap disc #3 is mounted on the back of the auger tube in the
center of the appliance and has a reset button. To access
it remove the right side panel. If the fi re tries to burn back
into the feed system or push exhaust up the feed tube, this
snap disc will shut the entire system off. This disc must be
manually reset.
20. Vacuum Switch
The vacuum switch is located on the lower right side of the
appliance behind right side panel. This switch turns the
feed system on when vacuum is present in the fi rebox. The
vacuum switch is a safety device to shut off the feed motor if
the exhaust or the heat exchanger system is dirty or plugged
or if the fi rebox door is open.
21. Wiring Harness
See Figure 41.1 below.
Hopper
Snap
Vacuum
Capacitor
Disc #2
Switch
Switch
Snap
Disc #1
Snap
Disc #3
7050-128B
M
Feed
Motor
M
Convection
Motor
M
Combustion
Blower
Fuse
R
Page 41

Advertisement

Table of Contents
loading

Table of Contents