High Ash Fuel Content Maintenance - Quadra-Fire SANTAFE-MBK Owner's Manual Installation And Operation

Santa fe pellet stove
Hide thumbs Also See for SANTAFE-MBK:
Table of Contents

Advertisement

R
B. High Ash Fuel Content Maintenance
Frequency: As needed
By: Homeowner
Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the fi repot fi ll quickly with ashes and
clinkers.
This condition makes the appliance susceptible to overfi lling
the fi repot with pellets which may result in smoking, sooting
and possible hopper fi res. Figure 34.1 shows an example
where the fi repot overfi lls, pellets back up into the feed tube
and ash has accumulated in the fi rebox.
An ineffi cient and non-economical method of burning of fuel
caused by poor quality pellet fuel
The correct fl ame size when good quality, premium pellet
fuel is burned is shown in Figure 34.3.
If the ash buildup exceeds the half way point in the fi repot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.
WARNING
Fire Risk.
• High ash fuels, or lack of maintenance, can
cause the firepot to overfill. Follow proper
shutdown procedure if ash buildup exceeds
half way point in firepot.
• Failure to do so could result in smoking,
sooting and possible hopper fires.
Page 34
Figure 34.2.
is shown in
7050-128B
Santa Fe Pellet Stove
Firepot Overfills
Ash Build Up in Firebox
Figure 34.1
Incorrect
Tall, Lazy Flame, Orange in Color
Figure 34.2
Correct
Correct Flame Size, Yellow/White in Color
Figure 34.3
Pellets Back Up
In Feed Tube
September 3, 2009

Advertisement

Table of Contents
loading