Hussmann P/N 0420057_B Installation And Operation Manual page 37

Service merchandisers
Table of Contents

Advertisement

P/N 0420057_B
REPLACING FAN MOTORS AND BLADES
See cross section for location of evaporator fans.
Should it ever be necessary to service or replace
the fan motors or blades be certain that the fan
blades are re-installed correctly. T
MUST BE INSTALLED WITH RAISED EMBOSSING
(
PART NUMBER ON PLASTIC BLADES
AS INDICATED ON THE PARTS LIST
case data sheet for each model.)
For access to evaporator fans:
1. Turn off power
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Lift fan plenum out of case. Place on stable
work surface.
5. Remove screws holding fan basket to plenum.
Fan blade may be removed after fan assembly
is removed from plenum.
6. Remove screws holding bottom of motor to
fan basket.
7. Replace fan motor and blade in fan basket.
8. Reinstall fan basket in plenum and reinstall
plenum in case.
9. Reconnect fan to wiring harness. Turn power
on.
10. Verify that motor is working and blade is
turning in the correct direction.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
SERVICE
HE BLADES
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
)
POSITIONED
at the main disconnect when servicing or
. (Refer to the
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.
WARNING
!
— LOCK OUT / TAG OUT —
3
4
5
Service Merchandisers
6-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impact

Table of Contents