KOBE CH0030SQB-1 Installation Instructions And Operation Manual

KOBE CH0030SQB-1 Installation Instructions And Operation Manual

Kobe brand range hood - ch-100 series (18” height) and ra-02 series (18” height)

Advertisement

KOBE Brand Range Hood
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
CH-100 Series (18" Height)
Model No.:
CH0030SQB-1 (30")
CH0036SQB-1 (36")
CH0042SQB-1 (42")
CH0048SQB-1 (48")
RA-02 Series (18" Height)
Model No.:
RA0230SQB-1 (30")
RA0236SQB-1 (36")
RA0242SQB-1 (42")
RA0248SQB-1 (48")

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CH0030SQB-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for KOBE CH0030SQB-1

  • Page 1 KOBE Brand Range Hood CH-100 Series (18” Height) Model No.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) RA-02 Series (18” Height) Model No.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...
  • Page 2 READ BEFORE INSTALLATION 1. Carefully check all contents of packages;  2. Thoroughly inspect the unit for any cosmetic damages or  defects;  3. Test the unit before installation;  4. Have a certified contractor/electrician do the installation.  IF THERE IS ANY PROBLEM: 1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL  PACKAGING MATERIAL.  2. Have your original proof of purchase and product serial  number ready.  3. Call 1‐877‐BUY‐KOBE (289‐5623); or e‐mail to  info@koberangehoods.com to report the problem.    NO RETURN, NO REFUND, NO EXCHANGE IF: 1. PRODUCT HAS BEEN INSTALLED  2. KNOCK‐OUT HOLES HAVE BEEN PUNCTURED  3. MISSING ORIGINAL PACKAGING MATERIAL AND/OR  PARTS ...
  • Page 3: Table Of Contents

    - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................3  COMPONENTS OF PACKAGE ....................5  INSTALLATION ..........................7  OPERATION INSTRUCTIONS ....................17  MAINTENANCE .......................... 18  SPECIFICATIONS ........................19  MEASUREMENTS & DIAGRAMS ....................21  PARTS LIST ..........................24  CIRCUIT DIAGRAM ........................
  • Page 4: Important Safety Instructions

    KOBE RANGE HOODS authorized agents will automatically void the warranty. KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
  • Page 5 What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
  • Page 6: Components Of Package

    COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) CH-100 Series RANGE HOOD BOX KOBE Range Hood – 1 Warranty Registration Card –1 Instructions Manual – 1 Oil Tunnel – 1 Baffle Filter - 2 (30” & 36”) - 3 (42”...
  • Page 7 (42” & 48” only) {H} Screws Package – 1 {I} Hood-Mounting Bracket – 1 {J} Screws Package – 1 BOX 2 OF 2 ITEM NO.: RA02DC Duct Cover FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.KOBERangeHoods.com CONTACT KOBE RANGE HOODS AT (626) 775-8880.
  • Page 8: Installation

    INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.) - FOR UNDER THE CABINET - TABLE 1 CH-100 Series A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood...
  • Page 9 SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. CH-100 SERIES – UNDER THE CABINET INSTALLATION ..............9  CH-100 SERIES –...
  • Page 10: Ch-100 Series – Under The Cabinet Installation

    CH-100 SERIES – UNDER THE CABINET INSTALLATION Figure 1 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. A straight, short venting run will allow the hood to perform more efficiently.
  • Page 11: Safety Warning

    Figure 5 Ductwork Installation 7. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above.
  • Page 12: Ch-100 Series – Stand Alone Installation

    CH-100 SERIES – STAND ALONE INSTALLATION ***This installation only applies with the purchase Figure 9 of an optional duct cover: Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside.
  • Page 13 5. Align hood-mounting bracket to the six screws Figure 12 on the wall and hook hood into place. Tighten screws to secure hood to the wall. 6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws not included).
  • Page 14 Figure 13 Duct Cover Installation 8. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above.
  • Page 15: Ra-02 Series - Installation

    RA-02 SERIES - INSTALLATION Figure 17 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. (Figure 16) A straight, short venting run will allow the hood to perform more efficiently.
  • Page 16 Figure 19 Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references in Table 2 and measurements on Page 23, mark the leveling locations point for hood-mounting bracket on the wall.
  • Page 17 Figure 22 Duct Cover Installation 6. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight.
  • Page 18: Operation Instructions

    OPERATION INSTRUCTIONS This KOBE hood is equipped with two rotary controls with powerful centrifugal squirrel cage, baffle filters, and bright LED lights. The two rotary controls are Light Control & Speed Control. Refer to Figure 28. Figure 28 Note: For best results, turn hood to QuietMode™ prior to preparation or cooking to establish airflow in the kitchen.
  • Page 19: Maintenance

    MAINTENANCE For the optimal level of operation, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2.
  • Page 20: Specifications

    SPECIFICATIONS CH-100 Series MODEL / SIZE CH0030SQB-1 / 30” / Single Blower CH0036SQB-1 / 36" / Single Blower CH0042SQB-1 / 42” / Dual Blowers CH0048SQB-1 / 48” / Dual Blowers COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE CH0030SQB-1 – 320W / 2.86A CH0036SQB-1 –...
  • Page 21 RA-02 Series MODEL / SIZE RA0230SQB-1 / 30” / Single Blower RA0236SQB-1 / 36" / Single Blower RA0242SQB-1 / 42” / Dual Blowers RA0248SQB-1 / 48” / Dual Blowers COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE RA0230SQB-1 – 320W / 2.86A RA0236SQB-1 –...
  • Page 22: Measurements & Diagrams

    MEASUREMENTS & DIAGRAMS All measurements in ( ) are millimeters. All inch measurements are converted from millimeters. Inch measurements are estimated. CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) - FOR UNDER THE CABINET - - FOR STAND ALONE -...
  • Page 23 - FOR STAND ALONE (WITH OPTIONAL DUCT COVER) - CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) ***Hood-Mounting Bracket Baffle Filters & Stainless Steel Spacer...
  • Page 24 All measurements in ( ) are millimeters. All inch measurements are converted from millimeters. Inch measurements are estimated. RA-02 Series MODEL NO.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”)
  • Page 25: Parts List

    DESCRIPTION MODEL /SIZE PART NO. Screw (3/16” x 3/8” ) L1-0707-0002 Hood Mounting Bracket L1-0221-1630 6” Round Plastic Exhaust CH0030SQB-1 / CH0036SQB-1 L1-0505-0001 8” Round Exhaust Plate CH0042SQB-1 / CH0048SQB-1 L1-0242-3630 CH0030SQB-1 / CH0036SQB-1 L1-0302-0120-802SS Air Chamber & Motor CH0042SQB-1 / CH0048SQB-1...
  • Page 26 CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”)
  • Page 27 CH-100 Series MODEL NO.: CH0042SQB-1 (42”) CH0048SQB-1 (48”)
  • Page 28 RA-02 Series MODEL NO.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”) DESCRIPTION MODEL /SIZE PART NO. 6” Round Plastic Exhaust RA0230SQB-1 / RA0236SQB-1 L1-0505-0001 8” Round Exhaust Plate RA0242SQB-1 / RA0248SQB-1 L1-0242-3630 Duct Cover RA02DC 12-02000-012-61 RA0230SQB-1 / RA0236SQB-1 L1-0201-0230 Hood Mounting Bracket RA0242SQB-1 / RA0248SQB-1...
  • Page 29 RA-02 Series MODEL NO.: RA0230SQB-1 (30”) RA0236SQB-1 (36”)
  • Page 30 RA-02 Series MODEL NO.: RA0242SQB-1 (42”) RA0248SQB-1 (48”)
  • Page 31: Circuit Diagram

    CIRCUIT DIAGRAM CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) RA-02 Series MODEL NO.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”)
  • Page 32: Trouble Shooting

    TROUBLE SHOOTING Issue Possible Cause Solution After Installation, The power is not on. Make sure the circuit breaker and the unit’s power is both motors and ON. Use a voltage meter to check the power supply. lights are not The wire connection is not secure. Check and tighten wire connection.
  • Page 33: Warranty

    TWO-YEAR LIMITED WARRANTY FOR PARTS AND LABOR ON KOBE PREMIUM SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will, at our sole discretion, choose to repair or replace the product free of charge that failed due to manufacturing defects.
  • Page 34 3. Have the model number 4. Have the serial number 5. Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE, PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER: KOBE SERVICE CENTER...
  • Page 35: Product Registration

    1. Date of purchase 2. Model No. 3. Serial No. For warranty service or spare parts purchase contact: KOBE Service Center Toll Free: 1-855-800-KOBE (5623) Email: kobe@adcoservice.com To report a problem, please contact: Toll Free: 1-877-BUY-KOBE (289-5623) Email: customer.service@koberangehoods.com...
  • Page 36 Arcadia, CA 91006 USA http://www.KOBERangeHoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country. Using a KOBE hood overseas is at your own risk and will void your warranty.

Table of Contents