Page 1
KOBE Brand Range Hood CH-100 Series (18” Height) Model No.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) RA-02 Series (18” Height) Model No.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...
Page 2
READ BEFORE INSTALLATION 1. Carefully check all contents of packages; 2. Thoroughly inspect the unit for any cosmetic damages or defects; 3. Test the unit before installation; 4. Have a certified contractor/electrician do the installation. IF THERE IS ANY PROBLEM: 1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL. 2. Have your original proof of purchase and product serial number ready. 3. Call 1‐877‐BUY‐KOBE (289‐5623); or e‐mail to info@koberangehoods.com to report the problem. NO RETURN, NO REFUND, NO EXCHANGE IF: 1. PRODUCT HAS BEEN INSTALLED 2. KNOCK‐OUT HOLES HAVE BEEN PUNCTURED 3. MISSING ORIGINAL PACKAGING MATERIAL AND/OR PARTS ...
KOBE RANGE HOODS authorized agents will automatically void the warranty. KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
Page 5
What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.) - FOR UNDER THE CABINET - TABLE 1 CH-100 Series A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood...
Page 9
SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. CH-100 SERIES – UNDER THE CABINET INSTALLATION ..............9 CH-100 SERIES –...
CH-100 SERIES – UNDER THE CABINET INSTALLATION Figure 1 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. A straight, short venting run will allow the hood to perform more efficiently.
Figure 5 Ductwork Installation 7. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above.
CH-100 SERIES – STAND ALONE INSTALLATION ***This installation only applies with the purchase Figure 9 of an optional duct cover: Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside.
Page 13
5. Align hood-mounting bracket to the six screws Figure 12 on the wall and hook hood into place. Tighten screws to secure hood to the wall. 6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws not included).
Page 14
Figure 13 Duct Cover Installation 8. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above.
RA-02 SERIES - INSTALLATION Figure 17 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. (Figure 16) A straight, short venting run will allow the hood to perform more efficiently.
Page 16
Figure 19 Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references in Table 2 and measurements on Page 23, mark the leveling locations point for hood-mounting bracket on the wall.
Page 17
Figure 22 Duct Cover Installation 6. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight.
OPERATION INSTRUCTIONS This KOBE hood is equipped with two rotary controls with powerful centrifugal squirrel cage, baffle filters, and bright LED lights. The two rotary controls are Light Control & Speed Control. Refer to Figure 28. Figure 28 Note: For best results, turn hood to QuietMode™ prior to preparation or cooking to establish airflow in the kitchen.
MAINTENANCE For the optimal level of operation, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2.
MEASUREMENTS & DIAGRAMS All measurements in ( ) are millimeters. All inch measurements are converted from millimeters. Inch measurements are estimated. CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) - FOR UNDER THE CABINET - - FOR STAND ALONE -...
Page 23
- FOR STAND ALONE (WITH OPTIONAL DUCT COVER) - CH-100 Series MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) ***Hood-Mounting Bracket Baffle Filters & Stainless Steel Spacer...
Page 24
All measurements in ( ) are millimeters. All inch measurements are converted from millimeters. Inch measurements are estimated. RA-02 Series MODEL NO.: RA0230SQB-1 (30”) RA0236SQB-1 (36”) RA0242SQB-1 (42”) RA0248SQB-1 (48”)
TROUBLE SHOOTING Issue Possible Cause Solution After Installation, The power is not on. Make sure the circuit breaker and the unit’s power is both motors and ON. Use a voltage meter to check the power supply. lights are not The wire connection is not secure. Check and tighten wire connection.
TWO-YEAR LIMITED WARRANTY FOR PARTS AND LABOR ON KOBE PREMIUM SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will, at our sole discretion, choose to repair or replace the product free of charge that failed due to manufacturing defects.
Page 34
3. Have the model number 4. Have the serial number 5. Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE, PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER: KOBE SERVICE CENTER...
1. Date of purchase 2. Model No. 3. Serial No. For warranty service or spare parts purchase contact: KOBE Service Center Toll Free: 1-855-800-KOBE (5623) Email: kobe@adcoservice.com To report a problem, please contact: Toll Free: 1-877-BUY-KOBE (289-5623) Email: customer.service@koberangehoods.com...
Page 36
Arcadia, CA 91006 USA http://www.KOBERangeHoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country. Using a KOBE hood overseas is at your own risk and will void your warranty.
Need help?
Do you have a question about the CH0030SQB-1 and is the answer not in the manual?
Questions and answers