Chicago Electric 95189 Operating Instructions Manual page 17

2200 rated watts/2400 max watts
Table of Contents

Advertisement

Powering 120 Volt AC Tools and Equipment:
1.
Prior to powering tools and equipment, make sure the Generator's rated voltage,
and amperage capacity (115 VAc / 20 AMPs) is adequate to supply all electrical
loads that the unit will power. If powering exceeds the Generator's capacity, it may
be necessary to group one or more of the tools and/or equipment for connection
to a separate generator.
2.
Once the Generator is running, simply connect the Power Cords of 115 volt AC
powered tools and equipment into the 115 volt AC Duel Outlets (6). (See Figure
G.)
3.
NOTE
: The Generator features an AC Non-Fuse Circuit Breaker (5) to protect the
AC circuit in case of an overload. Should an overload occur the Breaker will "trip"
to its "OFF" position, causing the Generator to automatically shut down. In this
case, refer to Step #1 above in this section. Then, reset the circuitry system by
turning the Circuit Breaker to its "ON" position. Restart the Generator and continue
powering the remaining tools and equipment. (See Figure D.)
4.
When finished using the Generator, turn the Engine Power Switch (2) to its
position. Turn the Fuel Valve (40B) to its "OFF" position. Then, disconnect all
electrical powered tools and equipment from the Generator's 115 volt AC Duel
Outlets (6). (See Figure E, F & G.)
5.
After the Engine and Generator have completely cooled, store the Generator in a
safe, clean, dry location (if not already installed in one).
Powering 12 Volt DC Tools and Equipment:
1.
Prior to powering a tool or equipment, make sure the Generator's rated voltage,
and amperage capacity (12 VDc / 10 AMPs) is adequate to supply all electrical
loads that the unit will power. If powering exceeds the Generator's capacity, it may
be necessary to group one or more of the tools and/or equipment for connection
to a separate generator.
2.
Connect the Power Cord of a 12 VDC powered tool or equipment to the DC Terminals
(7). NOTE: Make sure to connect the positive (+) lead of the Power Cord to the
positive (+) Terminal on the Generator, and connect the negative (-) lead of the
Power Cord to the Negative (-) Terminal on the Generator. (See Figure h, next
page.)
3.
If using only a 12 volt DC tool or equipment, turn the 120 volt AC Circuit Breaker
(5) to its "OFF" position. (See Figure D.)
SKU 95189
For technical questions, please call 1-800-444-3353.
"OFF"
Rev 10d
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents