8.
Keep all electrical equipment clean and dry.
sulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that
are worn, discolored, or corroded. Keep terminals clean and tight.
9.
insulate all connections and disconnected wires.
10.
Guard against electric shock.
as pipes, radiators, ranges, and refrigerator enclosures.
11.
Use only Class BC or Class ABC fire extinguishers on electrical fires.
NOTE
1.
: Prior to powering tools and equipment, make sure the Generator's rated
voltage, wattage, and amperage capacity (120V - 20 Amp's) is adequate to supply
all electrical loads that the unit will power. If powering exceeds the Generator's
capacity, it may be necessary to group one or more of the tools and/or equipment
for connection to a separate Generator.
2.
Electrical and other permits may be required for the installation of emergency or
portable power systems. Investigate the local building and electrical codes before
installing this unit. Installation must be completed by licensed contractors.
3.
WARNiNG
: The Generator weighs 91.5 pounds. Use care and the proper lifting
or hoisting equipment when moving it to the installation location. Always connect
hoist lines to the Frame (41B
1.
It is recommended to locate the Generator (outdoors only) where cooling air is
readily available.
2.
Install the Generator so that the air inlets and outlets are not blocked by obstruc-
tions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds
or snowdrifts may require the placement of a barrier for protection. The air inlet, in
normal weather conditions, should face the prevailing wind direction.
3.
Install the Generator on a concrete slab or other area where rain drainage or flood
waters can not reach it.
4.
Generator placement should allow four feet of access to all sides for mainte-
nance.
5.
Place the Generator as close as possible to the electrical tools and equipment be-
ing powered to reduce the length of extension cords.
6.
If the Generator is located indoors the Engine exhaust must be ventilated to the
outdoors using leakproof, heat resistant, flexible, metal, flex tubing.
SKU 95189
For technical questions, please call 1-800-444-3353.
Prevent body contact with grounded surfaces such
iNSTALLATiON
) of the Generator.
1
GENERAL LOcATiONS
Replace any wiring where the in-