Connection; Stopping The Engine - BOLIY Pro3600Si Owner's Manual

Electric start digital generator dsp technology
Hide thumbs Also See for Pro3600Si:
Table of Contents

Advertisement

CAUTION
• Be sure the battery leads are properly connected and is not damaged or obstructed.
• Be sure breather hose is properly connected and is not damaged or obstructed.
• Reduce the load to the specified generator rated output if the DC protector turns off.
If it turns off again, consult the authorized dealer.
NOTE:
• If short or overdraw should occur in the system, it will cause the DC Protector to trip. Press to reset
the DC protector.
NOTE:
• At full charge, electrolyte specific gravity is between 1.26 and 1.28
• Check specific gravity hourly.
WARNING
Never smoke near the battery while charging. Do not make or break connections while the
battery is charging. This may cause sparks to ignite the battery gas. Battery acid is poisonous
and dangerous; it contains sulfuric acid. Avoid contact with skin, eyes, and clothing as it will
cause severe burns.
If contact occurs:
EXTERNAL - Flush with water.
INTERNAL - Drink large quantities of water or milk, then drink milk of magnesia beaten egg or
vegetable oil. Call physician immediately.
EYES - Flush with water for 15 minutes and get prompt medical attention.
Batteries produce explosive gases. Keep sparks, flame, cigarettes, etc., away from the generator.
Ventilate when charging or using in closed space. Always cover eyes when working near batteries.
KEEP OUT OF REACH OF CHILDREN.

STOPPING THE ENGINE

1. Disconnect any electric devices.
2. Turn the engine switch to the "STOP" position.
3. Turn the fuel lever to "OFF"
1.
11
OPERATION CONTINUED
2.
STOP
ON
3.

Hide quick links: