Specifications - Bryant EVOLUTION 986TA Series Product Data

A series two-stage 4-way multipoise, variable speed condensing
Hide thumbs Also See for EVOLUTION 986TA Series:
Table of Contents

Advertisement

Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory- -shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
Heating Capacity and Efficiency
Input
High Heat
Low Heat
Output
High Heat
Low Heat
Efficiency
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Certified External Static
Pressure (in. w.c.)
Airflow Delivery @ Rated ESP (CFM)
Cooling Capacity (tons) @ 400, 350
CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections

SPECIFICATIONS

30040
(BTUH)
40,000
(BTUH)
26,000
(BTUH)
39,000
(BTUH)
25,000
AFUE % (ICS)
96.5
40 - 70
High Heat
(22 - 39)
30 - 60
Low Heat
(17 - 33)
30040
Heating
0.10
Cooling
0.5
High Heat
815
Low Heat
660
Cooling
905
CFM/ton
2
CFM/ton
2.5
1/2
6.8
in.
11 x 7
KGAWF1606UFR
30040
Volts-Hertz-Phase
Min-Max
Amps
7.5
Amps
10.3
AWG
14
Feet
36
(M)
(11.0)
Amps
15
Heating
Cooling
30040
2
Manufacturer
165
gas. The efficiency is GAMA efficiency rating certified. This
furnace meets California Air Quality Management District
emission requirements.
42060
48080
60080
60,000
80,000
80,000
39,000
52,000
52,000
58,000
78,000
78,000
38,000
50,000
51,000
96.3
96.2
96.5
40 - 70
40 - 70
40 - 70
(22 - 39)
(22 - 39)
(22 - 39)
30 - 60
30 - 60
30 - 60
(17 - 33)
(17 - 33)
(17 - 33)
42060
48080
60080
0.12
0.15
0.15
0.5
0.5
1135
1505
1555
860
1160
1200
1475
1610
2005
3.5
4
4
4.5
Electronically Communicated Motor (ECM)
3/4
3/4
8.4
8.4
10.9
600 - 1200
Variable (PWM)
11 x 8
11 x 8
11 x 10
Factory Supplied Media Cabinet
Field Supplied Filter
KGAWF1306UFR
KGAWF1406UFR
42060
48080
60080
115-60-1
104 - 127
9.2
9.2
11.7
12.4
12.4
15.5
14
14
29
29
(8.8)
(8.8)
(11.3)
15
15
40 VA
24.3 VA
34.6 VA
42060
48080
60080
1/2" - NPT
3
4
White Rogers
4.5
13.6
KGANP5201VSP
KGAPN4401VSP
not approved for MH use
Silicon Nitride
180
170
200
Adjustable: 90, 120, 150, 180 seconds
90 seconds
Evolution (non-zoning)
R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
3
60100
66120
100,000
120,000
65,000
78,000
97,000
117,000
63,000
76,000
96.1
96.5
40 - 70
40 - 70
(22 - 39)
(22 - 39)
30 - 60
30 - 60
(17 - 33)
(17 - 33)
60100
66120
0.20
0.20
0.5
0.5
0.5
1865
2375
1435
1675
2005
2115
5
5
5
5.5
5.5
6
1
1
1
10.9
10.9
11 x 10
11 x 11
KGAWF1506UFR
60100
66120
11.8
11.8
15.6
15.6
12
12
12
37
36
36
(11.0)
(11.0)
20
20
20
60100
66120
4
5
6
180
160

Hide quick links: