Repairs at the unit
17. Carefully tighten retainer nut (5) with adjusting wrench
18. Slide the top of the piston (3) into the T-slot (9) on the
slider assembly (4).
19. Position the pump manifold (2) underneath the gear unit
housing and push up until it rests against the gear unit
housing.
20. Attach pump manifold (2) to the gear unit housing.
21. Screw pump manifold (2) tightly to gear unit housing.
22. Lubricate O-ring (Fig. 11, Item 6) between pump manifold
(2) and inlet valve housing with machine grease. Screw
inlet valve housing to the pump manifold.
23. Insert the elbow on the siphon assembly into the bottom
of the pusher stem housing. Push the retaining clip up
into the groove inside the foot valve housing to secure the
siphon assembly in position. Place the return tube over
the return tube fitting and secure with the clip.
24. Install front cover.
11.4

ProSpray 3.21 connection diagram

Blue
Switch
White
EMI Filter
Ground
Black
P/N 0522054
Black
Ground
PC Board
Assembly
GB
Power Cord
L.E.D.
Circuit
Breaker
White Gray
Red
Black
Black
Pressure
Transducer
16
Potentiometer
P/N 0516360
Red (+)
Motor
Black (-)
P/N 0516360
Capacitor Assembly
ProSpray 3.21
Red (+)
Black (-)