Inverter Data - Platinum 3800 TL Installation And User Manual

Table of Contents

Advertisement

Inverter data

Weight
▪ 3800 TL, 3801 TL, 4300 TL
▪ 4800 TL, 5300 TL
▪ 6300 TL, 7200 TL
Dimensions (H x W x D)
Overvoltage category
reverse voltage protection (DC)
Ground fault monitoring
Protection class / overvoltage
protection
Optical display
Integrated datalogger
Switching concept
Cooling concept
▪ 3800 TL, 3801 TL, 4300 TL, 4800 TL
▪ 5300 TL, 6300 TL, 7200 TL
The technical data is valid for a maximum height of 2,000 m above sea
level.
Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
... TL
27 kg
28 kg
29 kg
720 x 320 x 250 mm
DC side: II
AC side: III
Yes
DC side: Isolation check
AC side: AfI
I / III
full graphic LCD, 170 x 76 pixels
Storage capacity sufficient for operating time
of 30 years
Transformerless, DIVE, rAC-MPP®
technology
Convection cooling
fan
Technical data
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4800 tl3801 tl5300 tl6300 tl4300 tl7200 tl

Table of Contents