Placing into operation
4.3.2 Description of the initial operation menu
Changing the date and time can cause saved data to be overwritten or
lead to gaps in data logging.
During initial operation, the date and time must be entered completely
once.
Initial operation menu
Start
Language
Network scan
Change
device
number/
reassign
numbers
24
Confirm prompt with OK.
Select the language required using the / buttons and confirm
with OK.
The inverter scans the PLATINUM® network connected and then
displays the number of participants and inverters in the network.
▪ If the number of participants and inverters is correct, confirm with
OK.
▪ If the number of participants and inverters displayed is not
correct:
– Check the wiring.
– Select rEPEAT using the / buttons and confirm with OK.
The inverter recognises only those network participants that are
correctly connected via the PLATINUM® network.
During initial operation, the inverter numbers are assigned
automatically in the network.
▪ If the numbers set automatically are to be retained, confirm
with NO and continue to the next menu option. The automatic
numbers for all inverters in the network are transferred.
Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL