Installation; Connecting A Camera Control Unit (Ccu); Attaching A Lens - Sony HSC-300 Operation Manual

Hd color camera
Table of Contents

Advertisement

Installation

Connecting a Camera Control Unit
(CCU)
When operating the camera in a system with a CCU, connect
between the CCU connector of the camera and the CAMERA
connector of the CCU, using a triax cable.
When required, secure the cable, using the supplied cable
clamp belt.
To use the cable clamp belt
1
Insert the belt bracket C into hole A or B of the cable
clamp belt.
C
2
1 Remove the back screw-hole cover on the top of
the camera and 2 secure the cable clamp belt to the
camera, using the two supplied screws (+B3
1
3
1 Release the buckle, 2 bundle the cable with the
belt, 3 then lock the buckle again.
1
B
A
×
10).
2
3
2
4
Adjust the length by pulling down the end of the belt.

Attaching a Lens

For information on handling lenses, refer to the operation
manual for the particular lens
V F
TE R
SH UT
W HT
OF F
ON
SE L
RE T
LE VE
M IC
CO M
IN ET ER
5
4
1
Push the lens fixing lever A upward and remove the
lens mount cap from the lens mount.
2
Align the lens' alignment pin C with the notch B in
the upper part of the lens mount and insert the lens
into the mount.
3
While supporting the lens, push the lens fixing lever
A downward to secure the lens.
4
Connect the lens cable to the LENS connector.
5
Secure the lens cable with the cable clamp.
To use a large studio-use lens
A large studio-use lens can be used with this camera by
mounting the camera on an optional HDLA1500-series Large
Lens Adaptor.
Note
When attaching the camera hangers to the camera, always
use the screws (+B4×10) supplied with the lens adaptor.
For details, refer to the operation manual supplied with the
HDLA1500-series adaptor.
B
A
1
3
C
2
BL K
L
Installation
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents