47 SKIP
Function: Selects the Memory Scan mode.
Available Values: SKIP / ONLY / OFF
Default: OFF
SKIP: The scanner will "skip" the flagged channels during scanning.
ONLY: The scanner will only scan channels that are flagged (Preferential Scan List).
OFF:
All memory channels will be scanned (the "flag" will be ignored).
48 SPLIT
Function: Enables/Disables split CTCSS/DCS coding.
Available Values: ON / OFF
Default: OFF
When this Set Mode Item is set to "ON," you will see the following additional parameters
after the "RV TN" parameter while configuring Set Mode Item "49 SQL.TYP."
D CODE: DCS Encode only.
T DCS:
Encodes a CTCSS tone and Decodes a DCS code.
D TONE: Encodes a DCS code and Decodes a CTCSS tone.
49 SQL.TYP
Function: Selects the Tone Encoder and/or Decoder mode.
Available Values: TONE / TSQL / DCS / RV TN / OFF
Default: OFF
TONE: CTCSS Encoder
TSQL: CTCSS Encoder/Decoder
DCS:
Digital Coded Encoder/Decoder
RV TN: Reverse CTCSS Decoder (Mutes receiver when matching tone is received)
Note: See also Set Mode Item "48 SPLIT" regarding additional selections available during
"Split Tone" operation.
50 STEP
Function: Sets the Synthesizer steps.
Available Values: 5 / 10 / 12.5 / 15 / 20 / 25 / 50 / 100 kHz
Default: 25 kHz
51 TEMP
Function: Indicates the current temperature inside the transceiver's case.
Note: Press the [ D/MR ( MW )] key repeatedly to toggle between Fahrenheit (°F) and Cel-
sius (°C) display of the temperature.