SECnON
400 (Version
3.0)
issue 1 January
1990
DBS
FF-8 LCR mode
FF&4#-(
1 - 4)#- (1 - 15)#-(000
- 999)#-(0
or l)#
Special
office
code table
storing
In order
to find the cheapest
outside
line group
to
be used from among
the numbers
starting
with
6
digits when
making
an LCR call, the call is made in
accordance
with the special
office
code for each
special area code specified
by the time priority
table.
Rather than the area code or ofice
code
being
determined
individually,
a telephone
number
of
6
digits
combining
the special
area code and special
office code is stored.
In this table
are stored 4 special
office code (000 -
999) tables
corresponding
to the 4 special area
codes.
The dial decided
on forthe
special office
code is
derived
from XXX as shown
below.
(N=2-9,P=O-1,X=0-9)
1 + Area code :
1 - NPX-XXX-XXXX
NON 1 + Areacode:
NPX-XXX-XXXX
Special
office
codes not stored
in thistable
cannot
be used for LCR calls. The structure
for the data
storing
in the table
is as follows.
I (Time prioritytable
number
l-15)
Time priority
table number
15#
I (Special
Office code number
l-4)
Special
Office code Table Number
4#
Time prioritytable
number
l#
Special
office code DATA:
(000-999)#-(Store:l
or Delete:O)#
I (Time prioritytable
number
l-15)
Time prioritytable
number
15#
Special
office code DATA:
(OOO-999)#-(Store:
1 or Delete:O)#
NOTE 7:
For the system installation
area it is
necessary
to set either
1 + Area or
Non
1 + Area.
NOTE 2:
LCR
calls cannot
be made
from outside
lines connected
to a
PBX.
Special
Office
code Table Number
1#
Time prioritytable
number
1#
Special
office
code DATA:
(OOO-999)#-(Store:1
or Delete:O)#
-69-