13.9

Panel Displays - - -

WARNING: RISK OF HYPERTHERMIA (OVER-
!
HEATING) CAUSING SEVERE INJURY, BURNS,
OR WELTS.
Water temperature is above acceptable limits. DO NOT ENTER SPA!
The safety "Watchdog" software has been triggered and the spa is
deactivated. A problem has been detected which could cause damage to
the spa or its components. Contact your authorized Sundance dealer.
13.10

Panel Displays BLB

UV lamp needs to be replaced. The message will flash
between "blb" and the water temperature. The timer for the
UV lamp must also be reset, refer to Section 10.9, page 34. A new UV
lamp can be purchased from a local Sundance Spas dealer.
14.0

Troubleshooting Procedures

In the event your spa is not working the way it should, please first review
all the installation and operating instructions in this manual and check the
message on the panel display. If you are still not satisfied it is working
properly, please follow the appropriate troubleshooting instructions below.
Note: If any of the supply cords to the accessories are damaged, they
must be replaced by authorized service personnel.
14.1

None of the Components Operate (e.g. Pump, Light)

Check the following when none of the spa components operate
(e.g. jets pumps or light):
1. Is there power to the spa?
2. Is the household circuit breaker tripped?
3. Call your authorized dealer.
14.2

Pump Does Not Operate but Light Does

Press the JETS 1 Button:
1. If no water movement is detected, make sure power is going to
the spa and check the water level. If it does not solve the problem,
contact your authorized Sundance dealer.
2. The main pump operates but no water flows to jets. Pump may not be
properly primed. This can happen after the spa is drained and refilled.
A. Press the JETS 1 button several times, never leaving the motor
on for more than 5 to 10 seconds at a time. Turn power off and
let the air out removing the filter cartridge. Refer to Section 11.1
(page 36). Make certain you reinstall the filter cartridge before
turning on spa power and restarting the jets pump.