12.2

Sanitizing

To destroy bacteria and organic compounds in the spa water, a sanitizer
must be used regularly. Chlorine and bromine are the two most popular
sanitizers used to date. Many other additives are available for your spa.
Some are necessary to compensate for out-of-balance water; some aid
in cosmetic water treatment and others simply alter the feel or smell of
the water. Your authorized Sundance dealer can advise you on the use of
these additives. When adding spa shock (chlorine or non-chlorine) or pH
balancing chemicals activate the jets pump(s) and leave the spa cover
open for a minimum of 20 minutes. By doing this you will allow excessive
chemical vapors to exit the spa, protecting pillows and plastic knobs from
chemical attack.
WARNING:
!
OR ENTRAPMENT!
Never leave your hot tub unattended for any reason while the
cover is open and accessible, especially to small children and
animals!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemicals may damage components
within your hot tub, burn or irritate your skin, create a rash
and void the manufacturer warranty for your spa.
12.3
CLEARRAY™ Water Purification System
Your new hot tub has our water purification system factory
installed that will begin disinfecting your water instantly.
CLEARRAY Water Purification System is exclusive
technology utilizing natural ultraviolet technology to sanitize your
water, disinfecting bacteria, viruses, and algae in portable hot
tubs. The ultraviolet light otherwise know as UV-C or germicidal
light inactivates the microorganisms by disrupting the DNA so that
it cannot reproduce and is considered lifeless. The ballast is the
power supply for the purification system; it has two LED indicator
lights the green indicating incoming power flow and the red
indicating the system is properly working. CLEARRAY is standard
for all models.
(For models with a circulation pump): The CLEARRAY System
only runs when the circulation pump is running and shuts off when
either jets pump is manually activated during spa use. The system
will remain off for 5 minutes after both jets pumps time out or are
manually turned off, then resume operations if the circulation pump is
programmed to run.
(For models without a circulation pump): The CLEARRAY System
only runs when the jets pump 1 is running.