Sundance Spas 680 Series Owner's Manual page 51

Hide thumbs Also See for 680 Series:
Table of Contents

Advertisement

11. Reinstall the compression washer (6) over the open end of the quartz
tube (2). Push it against the quartz black seal ring (13).
12. Reinstall and hand tighten the quartz seal compression nut (7) by
turning it clockwise.
13. Refill your spa.
14. System Test 1: Assure there is no water dripping from the seal
compression nut (7). If water is visible, STOP and tighten the
compression nut (7) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 13. Make sure there
is no water leaking before proceeding to step 15.
15. System Test 2: Turn breaker back ON. Turn on the pump to
circulate the water through the CLEARRAY System. Wait for 5
minutes and assure no water is dripping. If water is visible, STOP, fix
the leak by repeating quartz tube maintenance process from step 1
through step 14. Make sure there is no water visible and turn the
pump and breaker OFF BEFORE proceeding to step 16.
16. Reconnect the lamp socket (5) to the new UV lamp (4) make sure
you use the latex glove provided when handling the UV lamp.
Note: Align pins on UV lamp (4) to the receptacle holes on the lamp
socket (5) before inserting the pins completely into socket holes. Failure
to do so will damage the UV lamp.
WARNING:
YOUR BARE HAND. Oil on your skin will cause hot spot on
!
the UV lamp and shorten the life of your UV lamp. Use the
provided latex glove to handle the UV lamp.
17. Slide the new UV lamp (4) back inside the quartz tube, Figure 3.
18. Reinstall the black lamp boot (8) back over the quartz seal compression
nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with the
screws.
20. Reconnect the CLEARRAY System to the controller and turn on the
power to the spa.
21. Properly dispose of the old UV lamp.
WARNING:
!
which contains mercury. Dispose of the lamp in accordance
with disposal laws. See www.lamprecycle.org.
22. Once power is activated you can check the ballast
(12), Figure 7, to see if the CLEARRAY System
is functioning. A solid green light indicates that
the CLEARRAY System is being provided power and should
always be on. A solid red light indicates that UV lamp is
activated.
DO NOT TOUCH THE NEW UV LAMP WITH
This CLEARRAY System includes a UV lamp,
680 SERIES
Indicator
Lights
Figure 7
Page 45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents