8.13 MAIN PCB ASSY
(1) Disconnect the six FFCs and the three Connectors from the Main PCB ASSY.
(2) Remove the four Taptite cup S M3x6 SR screws, and then remove the FG harness
ASSY and Main PCB ASSY from the Main body.
Memo :
The five Taptite cup S M3x6 SR screws. (HL-2150N/2170W only)
FG harness ASSY
Taptite cup S M3x6 SR
Taptite cup S M3x6 SR
Taptite cup S M3x6 SR
(Only HL-2150N/2170W)
Main PCB ASSY
Note:
• After disconnecting the flat cable(s), check that each cable is not damaged at its end or
short-circuited.
• When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
Assembling Note:
If the FG harness ASSY which comes from the Laser unit is not connected, the Laser unit
break down.
Main PCB ASSY
FFC
Connector
Fig. 3-26
3-32
FFC
Connector
FFC