MASONRY FIREPLACE INSERT INSTALLATION (Cont.)
Installation Using a Direct Connection (Continued)
9. To install the surround panels, follow the directions listed in the section "INSTALLING SURROUND
PANELS" . NOTE: Surround panels are not required for a direct connection if a block-off plate is
used.
Follow the installation instructions in reverse order for periodic inspection and cleaning.
SIDE VIEW OF FIREPLACE INSERT DIRECT CONNECTION
Block-off Plate
Optional Surround
Panel
Non-Combustible
Material
Clay Flue Liner with
Required Air Space
Stainless Steel
Chimney Connector
Must Extend to Clay
Flue Liner or at least
one foot beyond
Block-off Plate
Airtight Insulated
Clean-Out
Remove Damper or
Wire it Open
Insulation
(Optional)
Block-off Plate
Insulation
18" Min.
Follow the directions on the previous page for installation.
The Extended Installation
is shown here. For the
flush or bay installation
follow the specifications
given for that type of
installation.