13.3.1
Diagnostic test of display board and LEDs
After accessing the diagnostics system, the display board is checked. All the LEDs and the display (if
featured) light in sequence.
When the buttons are pressed, the
corresponding or nearby LED lights; the
display shows the hexadecimal code
corresponding to the code for the button
pressed.
13.3.2
Programme selector
The table below lists the closure of contact C6 (common) with the rest
of the contacts (C1 – C5) on the programme selector in the various
positions and the corresponding code. The code is displayed only on
aappliances featuring a display panel.
Position of selector
1= This code is shown on the display
SOI/DT 2005-01 dmm
24-position type
1 - cancel
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Closure of selector contact
(C6 is the common contact)
C1
C2
C3
C4
0
1
1
1
0
1
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
0
0
1
1
0
0
0
1
0
0
0
1
0
0
1
0
1
0
1
0
0
1
0
1
0
0
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
1
1
0
1
1
1
1
0
0
0
1
1
0
0
0
0
0
0
1
0
0
0
0
0
1
0
0
1
0
53/65
Code
displayed
(1)
C5
1
1 E
1
0 6
1 4
0
0
0 C
0
1 C
1
0 A
0
0 1
1
0 3
0
0 9
0 E
1
1
1 2
1
0 b
0
1 1
0
1 8
1
1 3
1
1 A
1 9
0
1
1 b
0
0 5
1
1 6
1
0 2
0
0 4
0
0 8
1 0
0
599 36 82-56