Alarm
Description
E35
Overflow
Sensing circuit on anti-boiling pressure switch 1
E36
defective
Sensing circuit on anti-boiling pressure switch 2
E37
defective
Internal pressure takeoff is clogged (water level
E38
does not change for at least 30 sec. of drum
rotation).
E39
Defective HV sensing on anti-overflow system Main board defective.
E3A
Faulty sensing by heating resistance relay
E41
Door unlocked
E42
Problems closing the door
Defective triac supplying power to door delay
E43
system
E44
Defective sensing by door delay system
E45
Defective sensing by triac on door delay system Main board defective.
E51
Motor power supply triac short-circuited
E52
No signal from motor tachometric generator
E53
Motor triac sensing circuit faulty
E54
Motor relay contacts sticking
E61
Insufficient heating during washing
E62
Overheating during washing
E66
Heating element power relay faulty
E71
NTC sensor for wash cycle defective
Fault in NTC sensor on drying condenser
E72
(voltage out of range = short-circuit, open circuit)
SOI/DT 2005-01 dmm
Possible fault
Water fill solenoid valve is defective; Leaks from water circuit on
pressure switch; Pressure switch defective; Wiring defective; Main
board defective.
Main board defective.
Main board defective.
Water circuit on pressure switches;
Pressure switches;
Motor belt broken;
Main board defective.
Door lock unit defective; Wiring defective;
Main board defective.
Door lock unit defective; Wiring defective;
Main board defective
Door lock unit defective; Wiring defective;
Main board defective.
Main board defective.
PCB faulty; current leakage from motor or from wiring.
Motor faulty; wiring faulty; PCB faulty
PCB faulty.
PCB faulty; current leakage from motor or from wiring
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
PCB faulty; current leakage from heating element to ground.
Defective NTC sensor; Wiring defective;
Main board defective.
Drying NTC sensor (condenser) defective; wiring defective; main
circuit board defective.
58/65
Action/machine status
Cycle stops. Emergency drain
procedure. Drain pump continues to
operate (5 min. on, then 5 min. off,
etc.).
Cycle stops with door locked
Cycle stops with door locked
Heating phase is skipped
Cycle stops with door locked
Cycle stops with door locked
Cycle is paused
Cycle is paused
(Emergency drain procedure) Cycle
stops
(Emergency drain procedure) Cycle
stops
(Emergency drain procedure) Cycle
stops
Cycle blocked, door locked (after 5
attempts)
Cycle blocked, door locked (after 5
attempts)
Cycle blocked, door locked
Cycle blocked, door locked (after 5
attempts)
The heating phase is skipped
Safety drain cycle – Cycle stopped with
door open
Safety drain cycle – Cycle stopped with
door open
Heating is skipped
Heating is skipped
Reset
OFF/reset
OFF/reset
OFF/reset
---
OFF/reset
OFF/reset
Start
Start
OFF/reset
OFF/reset
OFF/reset
OFF/reset
OFF/reset
OFF/reset
OFF/reset
---
OFF/reset
OFF/reset
Start
Start
599 36 82-56