14.2.3

Behaviour of alarms during the diagnostic test

All alarms are operational during the diagnostic test on components. When the selector is turned to pass
from one test phase to another, it exits any associated alarm condition and performs the next selected test
(if the alarm does not recur).

14.3 Notes on the behaviour of certain alarms

Configuration alarms
E91: this error is indicated by the flashing of all the LEDs, and E90 is shown on the display if installed
E92: this error is indicated by the flashing of the LEDs located above the buttons, and E90 is shown on
the display if installed
E93: this error is indicated by the flashing of the LEDs indicating phases/warnings, and E90 is shown
on the display if installed
E95: this error is indicated by the flashing of all the LEDs, and E90 is shown on the display if installed
Alarms EB1-EB2-EB3: if the feed from the power supply is faulty, the machine will remain in the
alarm mode until the masters frequency or voltage returns to normal values or the appliance is
switched off. If this occurs, the "EB0" alarm family is displayed (on some appliances, the display of
alarms is disabled), the diagnostic mode cannot be accessed, and the "quick readout of alarms" mode
cannot be used. The alarm can be read only after the abnormal situation is corrected.

14.4 Quick display of alarms

The last alarm that has occurred can be displayed even if it is not in the tenth diagnostic position or the
machine is in the normal operating mode (for example, while the wash programme is in progress):
Press and hold down buttons 1 and 2 simultaneously for at least 2 seconds: the LEDs will first switch
off and will then show the sequence of flashes which indicates the alarm, or the code will be shown on
the display.
The alarm sequence will continue for as long as the buttons are held down
The method for interpreting this alarm is the same as the one described in paragraph 10.2.
While the alarm is displayed, the appliance will continue to operate.
programme selection mode, the options previously chosen will remain selected.

14.5 Cancelling the last alarm

After reading an alarm, it is good practice to delete it from memory in order to check whether it recurs
during the diagnostic test performed after the appliance is repaired.
1. Enter diagnostics mode and turn the selector to the tenth position (readout of alarms)
2. Press buttons 1 and 5 at the same time.
3. Hold buttons 1 and 5 pressed down for about 5 seconds.
SOI/DT 2005-01 dmm
56/65
If the appliance is in the
599 36 82-56