8. LV Standard Data Input

Adjust the normal coefficient of the light value.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note 1: Perform "Flange Back Adjustment" before this adjust-
ment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADYSHOT (Menu setting)
(CCD-TRV328/TRV428/TRV428E only) ....................... OFF
4) DISPLAY (Menu setting) ................................................ LCD
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
48
01
3
6
01
0D
4
6
02
5
0
03
1E
6
1
Note 5: The adjustment data will be automatically input to page:
F, address: 1A and 1B.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
48
00
3
0
03
00
4
0
01
00
CCD-TRV128/TRV228/TRV228E/TRV328/TRV428/TRV428E
RadarW
RadarW
RadarW
Procedure
Press PAUSE button. (Note 5)
Check the data changes to
"01".
Check that the displayed data
(Note 4) satisfied specified
value.
Procedure
Press PAUSE button.

9. Auto White Balance Standard Data Input

Adjust the white balance reference at 3200K.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Perform "Color Reproduction Adjustment" before this
adjustment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADYSHOT (Menu setting)
(CCD-TRV328/TRV428/TRV428E only) ....................... OFF
4) DISPLAY (Menu setting) ................................................ LCD
Preparations before adjustments:
Before performing the "Auto White Balance Standard Data In-
put", check the data of page: 3, address: FF.
If the data is 01, perform the work after turning on the power by
the following method.
1) Turn the power off once, if the data of page: 3, address: FF is
01.
2) Turn on the power of the set with the HOLD switch on the
adjustment remote commander left on the NOR side.
3) Change over the HOLD switch on the adjustment remote com-
mander to the ADJ side.
4) Execute the "Auto White Balance Standard Data Input"
Adjusting method:
Order Page Address Data
1
0
01
2
6
48
3
6
01
4
6
01
5
6
02
Note 4: The adjustment data will be automatically input to page:
F, address: 2A to 2D.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
48
3
0
01
6-19
CAMERA
Clear chart
(Color reproduction adjustment frame)
F
2A to 2D
Procedure
01
01
11
Press PAUSE button.
0B
Press PAUSE button. (Note 4)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
00
00