CCD-TRV128/TRV228/TRV228E/TRV328/TRV428/TRV428E
4-3.

SERVICE MODE

Additional note on adjustment
Note: After the completion of the all adjustments, cancel the ser-
vice mode by either of the following ways.
1) After data on page: D and C is restored, press the RE-
SET button and unplug the main power supply. (In this
case, date and time and menu setting have been set by
users are canceled. Perform resetting)
2) After data on page: D and C is restored, select page: 0,
address: 01, and return the data to 00. And when data
on page: 2 are changed, return data to the original con-
dition.

1. Setting the Test Mode

Page C
Data
00
Normal
01
Test mode
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page D
Data
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D and C, the data set will be recorded in the non-
volatile memory by pressing the PAUSE button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.