Electrolux TC2 Service Manual page 60

Washing machines & washer-dryers with electronic control system
Hide thumbs Also See for TC2:
Table of Contents

Advertisement

Alarm
E52
Motor faulty; wiring faulty; PCB faulty.
E53
PCB faulty.
E54
PCB faulty; current leakage from motor or from wiring.
E57
Motor defective; Wiring defective on inverter for motor, inverter board defective.
Motor defective; Wiring defective on inverter for motor, inverter board defective, abnormal
E58
motor operation (motor overloaded).
Motor defective; Wiring defective on inverter for motor;
E59
Inverter board defective.
Inverter board defective. NTC open (on the inverter board).
E5A
Overheating caused by continuous operation or ambient conditions (let appliance cool down).
E5B
Wiring defective, Inverter board defective.
E5C
Inverter board defective, the masters voltage is too high (measure the masters voltage).
E5D
Line interference, Wiring defective, defective main board or inverter board.
Defective wiring between main board and inverter board, Defective inverter board, defective
E5E
main board.
E5F
Defective inverter board, Defective wiring, defective main board
E61
Washing NTC sensor faulty; washing heating element faulty; wiring faulty; PCB faulty.
E62
Washing NTC sensor faulty; washing heating element faulty; wiring faulty; PCB faulty.
E66
PCB faulty.
E68
Earth-leakage between heater and earth.
E69
Washing heating element interrupted (thermofuse open)
Washing NTC sensor faulty; Wiring faulty;
E71
PCB faulty.
E72
Wiring faulty; NTC drying sensor faulty (condenser); PCB faulty...
E73
Wiring faulty; NTC drying sensor faulty (duct); PCB faulty.
E74
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty.
E82
PCB faulty (Wrong configuration data). Selector, wiring
E83
PCB faulty (Wrong configuration data). Selector, wiring
Wiring faulty; Faulty control/display board
E91
PCB faulty.
Wrong control/display board;
E92
Wrong PCB (do not correspond to the model).
E93
Incorrect configuration data; PCB faulty.
E94
Incorrect configuration data; PCB faulty.
SOI/DT 2007-06 dmm
Possible fault
60/75
Action/machine status
Cycle blocked, door locked (after 5
attempts).
Cycle blocked.
Cycle blocked, door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops.
Cycle stops with door locked (after 5
attempts).
The heating phase is skipped.
Safety drain cycle – Cycle stopped with
door open.
Safety drain cycle – Cycle stopped with
door open.
Cycle blocked with door open.
----------------
Heating is skipped.
Drying heating is skipped.
Drying heating is skipped.
Heating is skipped.
----------------
Cycle cancelled.
----------------
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Reset
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
ON/OFF
RESET
START/RESET
RESET
RESET
RESET
START/RESET
START/RESET
START/RESET
START/RESET
START/RESET
RESET
START/RESET
RESET
OFF/ON START
OFF/ON
OFF/ON
599 38 94-46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc3Tc4Ewm21 seriesEwm25 series

Table of Contents