Mira escape Installation & User Manual page 20

Thermostatic electric shower
Table of Contents

Advertisement

Symptom
Power.
Light
L o w o r n o
ON
flow.
ON
ON
ON
ON
ON
ON
Operation of
ON
t e m p e r a t u r e
c o n t r o l h a s
l i t t l e o r n o
ON
effect on water
temperature.
ON
ON
No change in
ON
t e m p e r a t u r e
between I/II/III
settings.
ON
Low.
Heater.
Flow.
Setting.
Light
I/II/III
ON
Any
Water supply pipework
or inlet filter restricted
by a blockage or partial
blockage.
ON
Any
I n s u f f i c i e n t
supply pressure/flow for
operation.
ON
Any
Other outlets (e.g. toilet,
garden hose, washing
machine, etc.) drawing
water while the shower is
being used.
OFF
Any
Handset blocked.
OFF
Any
Service tunnel or cover
not fitted correctly causing
Start/Stop button not to
operate.
OFF
Any
Inlet Valve faulty.
OFF
Any
Heater Tank excessively
scaled.
ON
II/III
Handset or inlet filter
blocked.
OFF
II/III
Inlet valve faulty.
OFF
II/III
Heater tank failure.
OFF
II/III
Microswitch failure.
ON
Any
Insufficient mains water
pressure.
OFF
Any
Possible failure of flow
valve, microswitch or
heater tank.
0
Probable.Cause
w a t e r
Possible.Remedy
Water supply pipework
or inlet filter restricted
by a blockage or partial
blockage.
C o n t a c t l o c a l w a t e r
company. Supply pressure
must be a minimum of
0.7 bar. Note: If other
appliances are operating,
pressure may drop below
0.7 bar.
Turn off other appliances
whilst shower is in use.
Remove and clean.
Check case inserts are
cut and fitted correctly.
Check services (electrical
or plumbing) are not
interfering with location of
service tunnel or cover.
Replace.
Replace. In hard water
areas consider the use of
a water softener.
Remove and clean.
Replace.
Replace.
Replace.
C o n t a c t l o c a l w a t e r
company.
Check the continuity of
the microswitch or heater
tank and replace parts as
neccessary.