Stove Installation

Chimney Requirements

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap.
Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.
Chimney must be fastened to each adjoining section.
Follow the chimney manufacturer's clearances and requirements.
Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling.
No more than 180
entire system (connector and chimney).
NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is
adversely affected. Additional chimney height may be required to boost draft.
(a) Min. System Height 15'
Max. System Height 33'
(b) Roof Penetration and Termination (see
chimney manufacturer's requirements)
(c) Chimney Sections
(d) Floor Penetration (see chimney manufacturer's
requirements)
(e) Min. air space to combustibles (see chimney
manufacturer's requirements – typically 2")
(f) Connector – see "Chimney Connector" on the
previous page.
Drafting
This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
Performance
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries cannot be
responsible for external forces leading to less than optimal performance.
© Travis Industries
o
o
of elbows (two 90
elbows, or two 45
(for qualified installers only)
o
o
& one 90
b
c
}
d
}
f
100-01334
elbow, etc.) may be used for the
}
b
f
11
e
a
Figure 4