Optional Equipment Requirements; Factory Built Chimney Requirements - Lopi Answer Owner's Manual

Residential freestanding stove • mobile-home freestanding stove • alcove approved • masonry fireplace insert • zero clearance (metal) fireplace insert
Hide thumbs Also See for Answer:
Table of Contents

Advertisement

S
TOVE
P
8
AGE
O
E
PTIONAL
QUIPMENT
¥
Must be installed with either the optional legs or pedestal
F
B
C
ACTORY
UILT
¥
Chimney connector must be a minimum 24 MSG black or 26 MSG blued steel
¥
Use 6" diameter type HT chimney from one manufacturer (do not mix brands). Chimney must
be used from the first floor or wall penetration to the chimney cap.
¥
Chimney connector and chimney must be fastened to the stove and each adjoining section
¥
Follow the chimney manufacturer's clearances and requirements
¥
Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when
passing through a ceiling (or thimble when passing through a combustible wall)
¥
Minimum height of 15 feet
NOTE: External factors may adversely affect draft (see "Drafting Performance" below). In
¥
Maximum height of 33 feet
¥
No more than 180
NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the
draft is adversely affected. Additional chimney height may be required to boost draft.
Chimney Cap
(See the section
"Chimney Termination
Requirements" for
more details)
Factory Built
Chimney
Sections
Floor Penetration
Equipment (Attic
Radiation Shield with
Chimney Support)
Reduceced
Clearance
Chimney
Connector
Sections
Floor
Protection
Drafting
This appliance relies upon natural draft to operate. External forces, such as wind,
Performance
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can
not be responsible for external forces leading to less than optimal performance.
I
NSTALLATION
R
EQUIREMENTS (See "Optional Equipment" starting on page 36
R
HIMNEY
EQUIREMENTS
these cases additional chimney height may be required to boost draft.
o
of elbows (two 90
}
}
(C
.)
ONT
o
elbows, or two 45
}
Roof Penetration Equipment
(Roof Radiation Shield,
Flashing, Storm Collar)
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Standard residential installations with
reduced clearance connector may use the
clearance determined by the manufacturer
of the connector for the connector to wall
clearance or the clearance listed in this
manual.
Mobile home installations must use the
the reduced clearance connector
clearances listed in this manual under
ÒAdditional Requirements for Mobile Home
InstallationsÓ.
Stove Clearance
(as outlined in this manual)
o
o
& one 90
elbow, etc.)
Minimum System 15'
Maximum System 33'