Summary of Contents for Lopi Endeavor

  • Page 1: Wood Stove

    E n d e a v o r Wood Stove Owner's Manual Freestanding Stove Mobile-Home Approved Alcove Approved Hearth-Stove Approved Save these instructions for future reference SAFETY NOTICE:...
  • Page 2 Introduction Introduction Important Information Mail your Warranty Card Today, and Save Your Bill of Sale.
  • Page 3: Installation Diagrams

    Table of Contents Maintaining Your Appliance General Information Stove Installation INSTALLATION DIAGRAMS Warranty Operating Your Appliance Listing Information Optional Equipment Index...
  • Page 4 ASHES 36" Type Clay Liner...
  • Page 5 Mobile Home This Manual...
  • Page 6 23-1/2” 24” 610mm 597mm 6” 152mm ø 5-3/4” 146mm 1-3/4” 44mm Note: Measure side, corner, and back clearances from the stove top. Measure front clearances from the stove face. Height: Sculptured or Cast Legs..30-5/8" 778mm Pedestal......34-5/8" 879mm Weight: 448 Lbs. 203 Kilos...
  • Page 10 Chimney Cap (See the section "Chimney Termination Requirements" for Minimum System 15' 4.57M more details) Maximum System 33' 10.05M Roof Penetration Equipment (Roof Radiation Shield, Flashing, Storm Collar) Factory Built Chimney Sections Floor Penetration Minimum Air Space to Combustibles Equipment (Attic (See Chimney Manufacturer's Radiation Shield with Instructions)
  • Page 11 Min. 2’ (610mm) 10’ (3.04M) Min. 3’ (914mm) Min. 2’ (610mm) 10’ (3.04M) Min. 3’ (914mm) Pedestal or outside air boot may The pedestal has an air be used to direct air from below opening for use with the the stove. See the pedestal outside air connections.
  • Page 12 Non-combustible alcove construction (on walls and ceiling) - see the explanation above. Ventilated air space Min. 3 1/2" (89mm) non- combustible material 1" (25mm) Min. Non-combustible reinforcer...
  • Page 13 Rear heat shield Measure all clearances from the nearest edge of the stove top. 12” Min. (305mm Minimum Connector Clearance (as outlined above) Minimum Stove Clearance (as outlined above)
  • Page 14 Chimney Cap (See the section "Chimney Termination Requirements" Follow the chimney for more details) manufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required Chimney Sections (some require a radiation shield). Insulation Follow the chimney manufacturer's instructions Minimum Air Space to and clearances for floor Combustibles (See...
  • Page 15 Follow the chimney Chimney Cap manufacturer's (See the section "Chimney instructions and Termination Requirements" clearances for roof for more details) penetrations. A storm collar and flashing are Chimney Sections required (some require a radiation Minimum Air Space to shield). Combustibles (See Chimney Manufacturer's Wall Bands Minimum 15' (4.57M)
  • Page 16 NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building Clay codes (UBC, etc.). Damage must be Liner repaired prior to installation.
  • Page 17 2 to 4 hours Rotate Swing the door the door handle. open.
  • Page 18 Bypass Pulled Out Used for starting and re-loading Use the included pull tool to operate the bypass rod Bypass Pushed In Used for normal operation...
  • Page 20 Use the air control to change the burn rate. Low Burn High Burn (air control closed) (air control open) ASHES...
  • Page 21 HIGH Turn the dial all the way counter- The high position is all the way counter- Turn the dial all the clockwise until it clicks off. clockwise, without clicking off. way clockwise. BLOWER BLOWER BLOWER CONTROL CONTROL CONTROL Creaks and Clicks: The 3/16"...
  • Page 22 Wood Wood Leads Leads Less More Heat Heat Leads Leads More Smoke Less Smoke and Creostoe and Creostoe Cut wood to length and Store the wood off the ground in a chop into quarters. covered area. Allow for airflow Air Flow around the wood to dry the wood.
  • Page 24 ASHES Allow the stove to fully cool. Apply glass cleaner or soapy water to the inside of the glass. Wipe with newspaper or a paper towel. For Stubborn Creosote: Dip newspaper or a paper towel in cool ashes and wipe it on the glass. The ash acts as a light abrasive.
  • Page 25 Use wood stove gasket High-Temperature anti-sieze cement to re-adhere may be used on the door loose gasket. hinges to eliminate squeaks. Severely frayed or thread-bare If the glass is damaged, replace it - see “Replacement Parts” for gasket should be replaced. details.
  • Page 26 Touch-Up P a i n t BOTTOM OF Use a vacuum cleaner to remove any STOVE buildup on the screens of the blower.
  • Page 27 1/8” Hex Wrench # 20 Torx Driver NOTE: Place the glass gasket around the perimeter of the door retainer. 9/16" Wrench NOTE: Glue the door gasket to the door retainer.
  • Page 29 Bypass Rod (& Yoke) Baffle Firebrick Front Baffle Support Bypass Damper Bypass Support Front Air Tube Bypass Gasket Support Tabs Center Baffle Support Air Tube Collar Air Tube Remove the left pin on the air tube collar Roll Pin Slide the air tube to the left, swing it down and remove from the firebox.
  • Page 32 Standard Screwdriver Rotate this shaft 1/4 turn clockwise until the door unlatches. Swing the door retianer open. Remove and discard the shipping latch and nut. Shipping Latch Door Retainer 9/16" Wrench Door Retainer Door Shell The indent on the door retainer slides into the clip on the door shell (on both sides).
  • Page 33 Make sure the door retainer is centered on the door shell. You can gauge the alignment by looking at the gaps here. 1/8” Hex Wrench Once the door is aligned, tighten the two set screws on the bottom of the door shell to secure the door retainer.
  • Page 34 Attach each leg to the stove by inserting a bolt and washer through the hole or slot in the leg and into the threaded hole on the stove. 9/16" Socket Wrench These rubber-tipped bolts are for leveling the stove. Make sure they contact the floor. Do not adjust with weight on the legs, the rubber tips may tear.
  • Page 35 Optional Air Intake Port If installing in a mobile home, Attachment Bolts and insert the lag bolts through Washers - use a 9/16" these holes and screw them socket wrench to into the floor with a 1/2" socket attach the pedestal to wrench.
  • Page 36: Optional Equipment

    Optional Equipment © Travis Industries 100-01161 4081014...
  • Page 37 Use a Bottom of Stove screwdriver to pry out the Attach the included knock-out (if applicable). gasket to all four top edges of the air boot. Attach the air boot with the two screws included with the kit. 1/4" Nutdriver Use the included screws to attach the two telescoping portions of air boot together.