E. Installing Wall Shield Firestops and Horizontal Termination Cap (SL Pipe)
WARNING
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Ensure vent components are locked together correctly.
• Pipe may separate if not properly joined.
For Horizontal Runs - Wall shield fi restops are REQUIRED on
both sides of a combustible wall through which the vent passes.
NOTE: Model SLK-01TRD does not need an exterior
wall shield fi restop on an exterior combustible wall.
To install wall shield fi restops for horizontal runs that pass
through either interior or exterior walls:
Cut a 10 in. x 10 in. (254mm x 254mm) hole for SL-D-
series pipe. The center of the framing hole is one (1) inch
(25.4mm) above the center of the horizontal vent pipe.
• Position the wall shield fi restops on both sides of the
hole previously cut and secure the wall shield fi restops
with nails or screws.
• The heat shields of the wall shield fi restops MUST BE
placed towards the top of the hole.
• Continue the vent run through the wall shield fi restops.
1 in. (25.4 mm)
Figure 8.14 Hole and Vent Pipe
HEAT SHIELD
WALLSHIELD
FIRESTOP
(INTERIOR)
Figure 8.15 Heat Shield, Interior & Exterior Firestops
36
10 in.
(254mm)
10 in.
(254mm)
VENT PIPE
TRIM HEAT SHIELD IF
TOO LONG.
USE EXTENDED HEAT
SHIELD (DVP-HSM-B) IF
TOO SHORT.
WALL SHIELD
FIRESTOP
(EXTERIOR)
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. D • 6/07
WARNING
Fire Risk.
Explosion Risk.
Do NOT pack insulation or other
combustibles between fi restops.
• ALWAYS maintain specifi ed clearances around venting
and fi restop systems.
• Install fi restops as specifi ed.
Failure to keep insulation or other material away from
vent pipe may cause fi re.
Installing the Horizontal Termination Cap
Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
Flash and seal as appropriate for siding material at out
side edges of cap.
When installing a horizontal termination cap, follow the cap
location guidelines as prescribed by current ANSI Z223.1
and CAN/CGA-B149 installation codes.
WARNING
Burn Risk
• Local codes may require installation of a
cap shield to prevent anything or anyone
from touching the hot cap.
WARNING
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Do NOT connect a pipe section to a termination cap
without using the telescoping fl ue section found on
the termination cap.
Failure to use telescoping fl ue section may cause a fi re
or exposure to exhaust fumes. Fireplace may not operate
properly.
NOTE: Where required, an exterior wall fl ashing is available.
When penetrating a brick wall, a brick extension kit is avail-
able for framing the brick.