Heat & Glo SL-550TR-E Owner's Manual page 12

Fireplaces
Hide thumbs Also See for SL-550TR-E:
Table of Contents

Advertisement

= VENT TERMINAL
V
A
= 12 inches ...............clearances above grade, veranda,
(See Note 1)
B
= 12 inches ...............clearances to window or door
D*
= 18 inches ...............vertical clearance to unventilated
*30 inches ..............for vinyl clad soffi ts and below
F
= 9 inches ................clearance to outside corner
G
= 6 inches .................clearance to inside corner
H
= 3 ft. (Canada) ........not to be installed above a gas
I
= 3 ft. .......................clearance to gas service regulator
J
= 9 inches (U.S.A.)
12 inches (Canada) clearance to non-mechanical
K
= 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor, or meets Note 2.
NOTE 1: On private property where termination is less than 7 feet above
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap
shield is suggested. (See vents components page)
NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specifi ed for
vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum
between termination caps. 2. All mechanical air intakes within 10 feet
of a termination cap must be a minimum of 3 feet below the termination
cap. 3. All gravity air intakes within 3 feet of a termination cap must be a
minimum of 1 foot below the termination cap.
Figure 4.4 Minimum Clearances for Termination
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
12
X
= AIR SUPPLY INLET
porch, deck or balcony
that may be opened, or to perma-
nently closed window. (Glass)
soffi t or to ventilated soffi t located
above the terminal
electrical service
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
vent outlet
air supply inlet to building or the
combustion air inlet to any other
appliance
ered) air supply inlet
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. D • 6/07
= AREA WHERE TERMINAL IS NOT PERMITTED
L** = 7 ft. ..........................c l e a r a n c e a b o v e p a v e d
M*** = 18 inches.................clearance under veranda, porch,
(See Note 1)
42 inches ................vinyl
S = 6 inches ...................clearance from sides of elec-
(See Note 5)
trical service
T = 12 inches ..................clearance above electrical
service
(See Note 5)
Alcove Applications
N
= 6 inches ..................non-vinyl sidewalls
12 inches ................vinyl sidewalls
P
= 8 ft.
Q
MIN
1 cap
3 feet
2 caps
6 feet
3 caps
9 feet
4 caps
12 feet
Q
= # termination caps x 3
R
MIN
MAX
NOTE 3: Local codes or regulations may require different
clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to
doors or other traffi c areas.
NOTE 5: Location of the vent termination must not interfere with
access to the electrical service.
WARNING: In the U.S: Vent system termination is NOT permitted in
screened porches. You must follow side wall, overhang and ground
clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow all side walls, overhang
and ground clearances as stated in the instructions.
Hearth & Home Technologies assumes no responsibility for the
improper performance of the appliance when the venting system
does not meet these requirements.
M
N
P
R
Q
(See Note 2)
V
T
S
S
Electrical
V
V
Service
D*
V
sidewalk or a paved driveway
located on public property
deck, balcony or overhang
R
MAX
2 x Q
ACTUAL
1 x Q
ACTUAL
2/3 x Q
ACTUAL
1/2 x Q
ACTUAL
= (2 / # termination caps) x Q
ACTUAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents