List Of Ups Monitoring Software Functions - Omron Powli BU50SW Instruction Manual

Table of Contents

Advertisement

Reference
E. List of UPS monitoring software functions
Software title
Function
Required separately available option
Windows Vista
Windows Server 2003 x64 Edition
Windows XP x64 Edition
Windows Server 2003
Windows XP/2000
Windows NT4.0
Windows Me/98
Linux
Mac OSX v10.4/Server v10.4
Mac OSX v10.3/Server v10.3
Auto shutdown
UPS monitoring (operating status)
UPS monitoring (data)
Pop-up notifi cation
End when OS is inactive (*3)
Auto fi le save (*3)
Schedule operation
UPS setting change
External command execution
Event log save
Data log save
Coordinated shutdown
Output receptacle control
Redundant power supply support
Remote UPS management
Mail send
SNMP management
Telnet connection
SYSLOG support
*1) UPS stops automatically only when the battery is depleted. (Battery Mode continues until this happens.)
*2) Only battery capacity monitoring can be performed.
*3) This function can be used with Windows only. It cannot be used with Linux.
[Explanation of software functions]
1 Auto shutdown
2 UPS monitoring (operating status)
3 UPS monitoring (data)
4 Pop-up notifi cation
5 Shutdown when OS is inactive
6 Auto fi le save
7 Schedule operation
8 UPS setting change
9 External command execution
10 Event log save
11 Data log save
12 Coordinated shutdown
13 Output receptacle control
14 Redundant power supply support
15 Remote UPS management
16 Mail send
17 SNMP management
18 Telnet connection
19 SYSLOG support
60
General applications
(Simple functions, standalone)
UPS service driver
Standard OS UPS service
▲(*2)
The computer can be shut down automatically when a problem occurs with the power supply.
The operating status of the UPS can be monitored (in Commercial Power Mode/Battery Mode).
Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
When a problem such as a power failure occurs, a pop-up window that shows the details of the problem can be displayed.
Shutdown can be performed when the computer is in an inactive state. The operating status is retained at shutdown in inactive
state, so operation details are not lost.
Files such as open Word and Excel documents are automatically saved at shutdown.
Schedule settings can be made for UPS stop/start.
UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be set vary according to the UPS.)
By executing commands at shutdown, items such as application programs can be launched.
Information of events that occur on the UPS (power supply problems, setting changes, occurrences of failure, etc.) are saved as
a log.
Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
When a problem occurs with the power supply, multiple computers connected to the UPS can coordinate to perform auto shut-
down.
The UPS output receptacles can be individually set to ON/OFF.
Two or more UPS can be connected to computers equipped with redundant power supply. Shutdown is not performed when a
power supply problem affects only one of the units.
Shutdown is performed only when a power supply problem occurs with both UPS, so the system's operating rate is improved.
UPS can be managed remotely from a computer on the network.
When a problem such as a power failure occurs with the power supply, a mail can be sent to the system administrator describ-
ing the details of the problem.
UPS management information can be sent to the SNMP manager.
Settings such as shutdown parameters can be made with the Telnet connection.
UPS management information can be recorded in SYSLOG.
Network management applications
(Advanced functions,
network support)
PowerAct Pro
BUC26
▲(*1)
Possible
Limited
SNMP management applications
(Advanced functions,
network support)
SNMP/Web card
SC20G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powli bu100swPowli bu150swPowli bu75sw