Specifications - Xantrex Truecharge2 Owner's Manual

Xantrex truecharge2 series battery chargers owner's guide
Hide thumbs Also See for Truecharge2:
Table of Contents

Advertisement

TC2 204060 Series BattChg Owners Guide.book Page 54 Friday, July 8, 2011 11:44 AM

Specifications

NOTE: Specifications are subject to change without prior notice.
Physical Specifications
Base Unit Dimensions: L × W × H
TC2012, TC4012
250×170×70 mm (9.84×6.70×2.76 in.)
TC1024, TC2024
250×170×70 mm (9.84×6.70×2.76 in.)
TC6012, TC3024
340×170×90 mm (13.38×6.70×3.54 in.)
Weight
TC2012, TC4012
2.2 kg (4.8 lbs)
TC1024, TC2024
2.2 kg (4.8 lbs)
TC6012, TC3024
4.5 kg (9.9 lbs)
AC input connections
Three color-coded No. 14 AWG wires (L, N,
) minimum 152 mm (6 in.) long in a
GND
separate AC wiring enclosure with 21.3 mm
(0.84 in.) hole provision for connection of a
½ inch North American "trade size" strain
relief (included).
AC input connections
IEC 60320 C14 male connector receptacle
(IEC models only)
DC output
Four M6 studs (3 positives and 1 common
connections
negative) for battery cable ring terminals and
one M6 mm DC equipment ground
54
AC Input Specifications
AC input voltage range
Nominal:
120 Vac, 230 Vac, 240 Vac
Full Performance:
104 – 265 Vac ±4 Vac
Automatic derating to
80% output:
90 – 108 ±4 Vac
Max. AC input current
TC2012:
3.9 A
TC4012:
7.7 A
TC6012
11.6 A
TC1024:
3.9 A
TC2024:
7.7 A
TC3024
11.6 A
≥0.95
Power factor at rated
load
Frequency
47 – 63 Hz
Efficiency – peak
12/24-volt units:
80% @ 120 Vac
12/24-volt units:
84% @ 230 Vac
Surge protection
Line-to-neutral surge protector rated at
275 Vac
Truecharge2 Series Battery Charger Owner's Guide