European Home DV 42 Installation, Operation And Maintenance Manual

European home dv 42 gas fireplace - installation, operation and maintenance manual

Advertisement

Quick Links

XW2002
XW2004
C
DANGER
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage
or
even
death.
For
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
US
Installation,
Operation and
Maintenance
Manual
DV 42
Gas
Fireplace
Check local codes and read all
instructions prior to installation.
XW2006
XW2012
XW2014
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
NOTICE
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
not use any phone in your building.
Hot surface
Danger of entrapment
Danger of death
General Warning
Laser Radiation
Biohazard
Oxidising
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
supplier's instructions.
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
If you cannot reach your gas supplier,
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
call the fire department.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV 42 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for European Home DV 42

  • Page 1 Installation, Operation and Maintenance Manual DV 42 Fireplace Check local codes and read all instructions prior to installation. DANGER WARNING Read and understand this manual. Do not store or use gasoline or any Improper installation, adjustment, other flammable vapors and liquids in...
  • Page 2: Table Of Contents

    SIT Pilot Burner Adjustment ............24 Section 3-3-1: Venting Layout ..........11 - 12 Troubleshooting ................25 Top Vent, Wall mounted Graph, DV 42 ........11 SIT- Nova 820 Gas Control Valve ..........25 Top Vent, Wall mounted termination (one elbow) .....11 SIT- IPI Electronic Gas Control Valve ........25 Top Vent, Wall mounted termination (multi elbow) ..11...
  • Page 3: Safety Alert Key

    Congratulations on your purchase of a European Home Fireplace. European Home is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Section A: Before you Begin IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS Installation Checklist The DV 42* direct vent fireplace must be installed in accordance „ Determine the desired install location of your fireplace. with these Instructions. Carefully read all the Instructions in See Section 1, Dimensions on Page 5, and refer to the „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    The DV 42* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, The fireplace dimensions are shown below: 39½"...
  • Page 6: Clearances

    N.G. Combustible 90 elbow Shelf N.G. & L.P European Home supplies a variety of direct venting and termination options. The direct vent termination location 21” 10” MUST be selected such that it is the highest point in the venting N.G.
  • Page 7 NOTES FOR PLANNING VENTING: Framing Heat Shield Included with the DV 42 Gas fireplace, is a framing heat shield Venting can originate from the unit through the top or through kit. This kit is fabricated from galvanized steel and arrives with the rear.
  • Page 8: Section 3-2: Installing A Roof Mounted Termination

    DV 42 Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED PVTK1 TERMINATION (PVTK-1) Termination 2’ min. This section applies to installations where the direct vent termination will be roof mounted. Support ring Section 3-2-1: VENTING LAYOUT Support plate 32’...
  • Page 9 When penetrating a combustible ceiling, a ceiling termination. Use only European Home vent components. Use firestop must be used. of non-European Home parts will void the warranty and may impede operation of the fireplace. • European Home recommends that all exterior corners...
  • Page 10 DV 42 Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT 4). Installation of Termination From Inside Structure TERMINATION A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction.
  • Page 11: Top Vent (Two Elbows One Offset)

    Figure 14 to ensure the layout is acceptable. Notes for Wall Mounted Terminations: Top Vent • All measurements for vertical or horizontal runs are Figure 14. DV 42* Top Vent Venting Graph for wall mounted measured from center of the vent pipe. terminations. •...
  • Page 12 Important 45° or less Corner Installation. Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12" A corner installation is available for DV 42 Top or 24" compressed length) and a frame, if appropriate. Flex Vent units ONLY. may be turned to obtain desired degree of angle required but must not exceed 45°.
  • Page 13: Rear Vent, Wall Mounted Termination (Two Elbows)

    Wall Figure 17b. Rear Vented, wall mounted multi-elbow termination Acceptable vent run installation. Installation for DV 42* must have a minimum vertical within non-shaded area. rise of 46". The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 17.
  • Page 14: Section 3-3-2: Venting Components

    Use only European Home vent components. Use of non-European Home parts will void the warranty and may • European Home recommends the use of a flex section impede operation of the fireplace.
  • Page 15: Section 3-3-3: Heat Shields

    DV 42 Indoor Gas Fireplace Installation installing a wall Mounted rHS101 Heat shield. Section 3-3-3: Heat Shields The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 19 and 19a) CANNOT be used. Use the installing a wall Mounted rHS8 Heat Shield...
  • Page 16: Section 4: Wiring

    Figure 21. Wiring for the SIT IPI Wiring Schematic wiring for the optional Fan Kit All DV 42* fireplaces may be equipped with an optional fan kit for circulating heat into the living space. Installations in Canada which employ the fans must be electrically grounded in accordance with CSA C22.1 Canadian...
  • Page 17: Section 5: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. DO NOT connect the fireplace to pressures in excess of • European Home requires a service shut-off valve be 1/2lb. This will damage the gas control valve. located in an accessible location to isolate the gas supply.
  • Page 18: Section 6: Finishing

    DV 42 Indoor Gas Fireplace Installation Section 6: Finishing What is Combustible? Finishing Around the Fireplace Materials that can catch fire and burn are considered Combustible mantels and mouldings may be safely installed combustible. Any material that is made of, or faced with, wood,...
  • Page 19: Section 7: Installing And Removing The Door

    Removing the Door edge of the fireplace and securely fastened in place to the metal The DV 42* doors are removed in a few simple steps. Follow lintel and combustible wood framing. these below to remove the horizontal access panel, unlatch the Note: The nailing flange extension can be substituted with a door buckles and, remove the door.
  • Page 20: Section 8: Installing The Accessories

    Installing the Glass Beads and Optional Fire Media Step 5: Ensure the tool is firmly The DV 42 fireplace is supplied with glass beads. Optional stone in the lower end of the and driftwood fire media are available. slot, as shown, then pull toward you.
  • Page 21: Operation

    DV 42 Indoor Gas Fireplace Operation Section 9: Start-up Sequence Model DV 42 with Continuous Pilot with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 22: Section 9: Operation

    DV 42 Indoor Gas Fireplace Operation Model DV 42 E Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 23: Maintenance

    Lighting Instructions See pages 21 to 22. Hi-Lo Burner Adjustment: (SIT Nova 820). General The DV 42* is equipped with an adjustable burner, allowing Have the fireplace and installation inspected yearly. The you to raise or lower the flames. To adjust the flames, locate...
  • Page 24: Troubleshooting

    DV 42 Indoor Gas Fireplace Maintenance Replacement Parts List Troubleshooting: (SIT Nova 820). Models DV 42 DV 42 DV 42 E NG Gas Valve RGC1006 RGC1004 LP Gas Valve RGC1005 RGC1003 The following is a troubleshooting chart of possible problems:...
  • Page 25: Appendix

    DV 42 Indoor Gas Fireplace Appendix Appendix A: Termination Locations A = clearance to the termination frame above grade, veranda, porch, (46 cm) minimum] deck, or balcony [16 inches (41 cm) minimum] S = clearance from corner in recessed location [12 inches (31 cm)
  • Page 26: Warranty

    Company negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this European Home Gas Appliance is limited to the duration of the foregoing warranty.
  • Page 27: State Of Massachusetts

    DV 42 Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft.
  • Page 28 EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington St. Suite 203 Malden, MA 02148 tel: 781/324-8383 fax: 781/324-8384 www.europeanhome.com rev.110328...

Table of Contents