European Home GVF-42 Installation, Operation And Owner's Manual

The g series linear ng burner – dual listed, vented and vent free.

Advertisement

G S E R I E S
L i n e a r · H e a r t h · B u r n e r
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
-- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
G Series Linear Hearth Burner
This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilating air must be
provided. Refer to page 6.
This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
Report #284-F-08-4
1
Installation,
Operation
and
Owner's Manual
Models:
GVF-42
GVF-60
GVF-72
EuropeanHome.com
Nov. 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GVF-42 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for European Home GVF-42

  • Page 1 G S E R I E S Owner’s Manual L i n e a r · H e a r t h · B u r n e r Models: GVF-42 GVF-60 GVF-72 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information Room Volume for Vent Free Specifications and Dimensions Pre-installation Planning Electric Installation Gas Installation Installing the Burner Operating the Burner Maintenance Parts List Warranty Appendix A Product Installation Record Appendix B Troubleshooting Appendix C EuropeanHome.com G Series Linear Hearth Burner...
  • Page 3 IMPORTANT SAFETY INFORMATION Read these instructions carefully before installing or trying to operate this Vent Free gas heater. • Any change to this heater or its controls can be dangerous. • Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
  • Page 4 IMPORTANT SAFETY INFORMATION Read these instructions carefully before installing or trying to operate this Vent Free gas heater. 11. Correct installation of the fire media, proper location of the heater, and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace.
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Read these instructions carefully before installing or trying to operate this Vent Free gas heater. 20. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 6: Room Volume For Vent Free

    ROOM VOLUME for VENT FREE CODES Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
  • Page 7 Maximum BTU/hr. my space will support (use formula above) a) __________________ BTU/hr. of European Home G Series Linear Hearth Burner b) ____37,500________ If the answer to a) is greater than b) then your space will support the installation of the G Series Linear Hearth Burner; if a) is less than b) then your space will not support an G Series Linear Hearth Burner.
  • Page 8 SPECIFICATIONS and DIMENSIONS SPECIFICATIONS G Series Linear Hearth Burner Fuel Natural Gas ONLY Manifold Pressure 3.5” (0.87 kPa) Minimum Supply 4.0” (1.0 kPa) Pressure Maximum Supply 7.0” (1.7 kPa) Pressure Orifice Size #47 DMS Input (High, BTU/hr.) 37,500 Input (Low, BTU/hr.) 25,000 Electrical 6V DC 500mA...
  • Page 9 SPECIFICATIONS and DIMENSIONS Figure 1. Burner Cover Dimensions Figure 2. Burner Base Dimensions Dimension GVF-42 GVF-60 GVF-72 47.2” 60” 77” 16.23” 16.23” 16.23” 5.28” 5.28” 5.28” 38.43” 49.24” 59.27” 5.10” 5.10” 5.10” 43.38” 43.38” 43.38” 6.5” 6.5” 6.5” Table 2. Dimensions by Model EuropeanHome.com...
  • Page 10: Specifications And Dimensions

    EUROPEAN HOME Apply loose material per instruction manual. DO NOT apply extra material or material 376 Washington Street not supplied with the heater. Replace only with European Home Fire Media approved Malden, MA 02148 for G Series Linear Hearth Burners.
  • Page 11 SPECIFICATIONS and DIMENSIONS GVF-42 GVF-60 GVF-72 47” 65” 77” (Opening Width) 433/8” 491/8” 591/4” (Opening Width without Cover) 18” 18” 18” (Distance to Lintel) 153/4” 153/4” 153/4” (Fireplace Depth) (Flue Opening) sq. in. sq. in. sq. in. Table 3. Minimum Fireplace Dimensions (with Cover) Required by Model...
  • Page 12 PRE-INSTALLATION PLANNING BEFORE YOU BEGIN Thank you for purchasing an G Series Linear Hearth Burner by European Home. This product has been de- signed to provide you with safe, trouble-free operation. Please read this manual thoroughly before beginning the installation. It has information which is important for safe installation and operation.
  • Page 13 PRE-INSTALLATION PLANNING APPROVED INSTALLATIONS The G Series Linear Hearth Burner has been certified to two standards: - ANSI Z21.11.2b-2011, for unvented room heaters - ANSI Z.21.60-2012/CSA 2.26-2012, for vented decorative appliances Check the local/state codes to determine if unvented heaters are permitted at your location before installing this product as a vent-free appliance.
  • Page 14: Pre-Installation Planning

    PRE-INSTALLATION PLANNING MANTEL CLEARANCES 12.0” maximum Combustible mantel 11.0” minimum Top of existing fireplace opening Existing fireplace opening Figure 5. Combustible Mantel Clearances Combustible mantels may be no closer to the fireplace opening than 11.0” or deeper than 12.0”. See Figure 4 (side view,) above. EuropeanHome.com G Series Linear Hearth Burner...
  • Page 15: Electric Installation

    ELECTRIC INSTALLATION WARNING When servicing controls label all wires prior to disconnection. Wiring errors can cause improper and dangerous operation. This appliance must be electrically grounded in accordance with local codes, or, in the absence of local codes, with either the National Electrical Code ANSI/NFPA 70.
  • Page 16 ELECTRIC INSTALLATION Figure 7. Electrical Schematic for G Series Burner Battery Case Jack EuropeanHome.com G Series Linear Hearth Burner...
  • Page 17: Gas Installation

    GAS INSTALLATION Note The installation of this product must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 This product is shipped from the factory for use with natural gas ONLY. Conversion to another fuel is NOT permitted. This product must be installed by a licensed plumber or gasfitter when installed within the Commonwealth of Massachusetts.
  • Page 18: Installing The Burner

    INSTALLING the BURNER Place the burner in the center of the fireplace and connect the gas supply to the flexible connector attached to the burner. Figure 9. Burner Base After the gas supply has been connected, open the main supply and check all of the fittings for gas leaks.
  • Page 19 Although the fibers have a long life, they will eventually deteriorate. If this becomes apparent, replacement Embaglow can be purchased from your local fireplace retailer or European Home. BEFORE THE FIRST FIRE 1.
  • Page 20 OPERATING the BURNER RESETTING THE SYSTEM (Pairing the Remote and Receiver) The G Series Linear Hearth Burner should need to be reset only once, prior to initial use. This is done as follows: 1. Press and hold the receiver reset button (Figure 10) until you hear the second of two beeps. 2.
  • Page 21 OPERATING the BURNER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
  • Page 22: Operating The Burner

    OPERATING the BURNER USING THE REMOTE CONTROL ELECTRONIC IGNITION SYSTEM Setting °C/24 Hour or °F/12 Hour Clock. Press OFF and SMALL FLAME to toggle between °F/12 hr and °C/24 hr clock. Setting the Time. Simultaneously press the SMALL FLAME and LARGE FLAME buttons, the display now flashes. Press LARGE FLAME to set the hour and SMALL FLAME to set the minute.
  • Page 23 OPERATING the BURNER Timer Mode. The appliance must be in standby mode; pilot ignited. The Timer setting allows you to set two burner Temp times and two burner Temp times every 24 hrs. For Temp to operate as a thermostat, TEMP must be set at 4°C/40°F or higher. If the Temp setting is decreased to - -, the motor will turn the valve to the standby position in the ...
  • Page 24: Maintenance

    MAINTENANCE A qualified service agency should conduct an annual inspection and maintenance of your G Series Linear Hearth Burner to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the fireplace that are removed for servicing must be replaced prior to operation.
  • Page 25: Parts List

    G SERIES LINEAR HEARTH BURNER PARTS LIST G6R-R3AM Receiver G6R-H3T Remote Control 84008202000 SIT Pilot Burner Assembly AC Adapter AC Adapter for Receiver For replacement parts and customer service, contact: EUROPEAN HOME +1 (781) 324-8383 EuropeanHome.com G Series Linear Hearth Burner...
  • Page 26 The G Series Linear Hearth Burners European Home warrants the gas controls and burner of the G Series Linear Hearth Burner against defects in materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase.
  • Page 27 APPENDIX B PRODUCT INSTALLATION RECORD Installer: Please complete this form. Customer: Please retain this information. Purchased From Date of Purchase Installed By Date of Installation Serial Number Fuel Type NATURAL GAS EuropeanHome.com G Series Linear Hearth Burner...
  • Page 28 APPENDIX C FUNCTION POSSIBLE CAUSE REMEDY Replace transmitter batteries. Quality 9V Transmitter batteries low. alkaline recommended. Press UP and OFF buttons Replace transmitter batteries. Quality 1.5V to start ignition sequence. Receiver batteries low. AA alkaline recommended. Beep will occur each second.
  • Page 29 APPENDIX C FUNCTION POSSIBLE CAUSE REMEDY Check cable connection between receiver TC- and SW-cable reversed. and interrupter block. Pilot lit. Magnet unit not operating properly. Replace gas valve. Short between interrupter and SW cable. Check interrupter block connection. No gas (magnet unit drops after 30 second Check gas supply.
  • Page 30 EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington Street Suite 203 Malden, MA 02148 www.europeanhome.com IGGVF01-141124u EuropeanHome.com G Series Linear Hearth Burner...

This manual is also suitable for:

Gvf-60Gvf-72