European Home DV 42 ST Installation, Operation And Maintenance Manual

European Home DV 42 ST Installation, Operation And Maintenance Manual

See-through

Advertisement

Quick Links

Warning:
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information consult a
qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the
fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
®
C
US
Installation,
Operation and
Maintenance
Manual
DV 42 ST
See-through
Gas
Fireplace
Check local codes and read all
instructions prior to installation.
Warning:
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Installer: Leave this manual with
the appliance.
Consumer: Leave this manual for
future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV 42 ST and is the answer not in the manual?

Questions and answers

Summary of Contents for European Home DV 42 ST

  • Page 1: Safety Notice

    Installation, Operation and Maintenance Manual DV 42 ST See-through Fireplace Check local codes and read all instructions prior to installation. Warning: Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or What to do if you smell gas property damage.
  • Page 2: Table Of Contents

    Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a European Home gas fireplace, an elegant This owner's manual should be retained for future reference. We suggest and well designed gas fireplace built with you in mind. The gas fireplace...
  • Page 3: Introduction

    About this Fireplace: located out of traffic and away from furniture and draperies. The DV 42 ST (See-thru) is a fireplace with a linear-style burner. This fireplace can Children and adults should be alerted to the hazards of the ...
  • Page 4: Installation

    DV 42 ST See-through Gas Fireplace Installation Supplied shield Frame in the enclosure for the unit with framing materials. The framed opening Combustible Shelf for the assembled fireplace is 45" wide, x 40" high x 23 3/4" deep, see Figure 2 2”...
  • Page 5: Gas Installation

     Installing The Remote Switch The DV 42 ST gas valve, located behind the lower trim, may be connected to a wall switch. The valve generates its own power on a millivolt circuit. Use only low voltage wire, and DO NOT connect any external power to it.
  • Page 6: Installing The Nailing Flange

    DV 42 ST See-through Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations PTO-4 (5"/8") PTKOG (5"/8") Figure 5a. Installing a PTO termination. Figure 5d. Installing a PTO termination heat guard. Frame the termination opening to 11" x 11".
  • Page 7: Top Vent Venting Runs

    Product page). Figure 8b. RHS101 Installation. (Install by sliding over vent pipe where it passes through the combustible construction. Figure 7b. DV 42 ST Top Vent Venting Graph NOTES: All dimension lengths for vertical or horizontal runs are measured from center of the vent pipe.
  • Page 8 DV 42 ST See-through Gas Fireplace Installation Note: Flame characteristics will change if the maximum vent height is used. A maximum of two offsets (each offset has two 90° bends) may be made and  shall not exceed total length of 25% of the vertical vent height, when measured center to center of piping.
  • Page 9: Horizontal Vent Installation

    Screw the shield in Figure 15. Side Venting of DV 42 ST. (Must be as shown in Figure 15, 16, 17, 17a, place over the wall opening. Install the second section on the outside of the wall and 17b.)
  • Page 10 DV 42 ST See-through Gas Fireplace Installation Vertical Vent Installations  Vertical vent Installations. • minimum 2' (two feet) above the highest point where vent passes through the roof. Solid • minimum 6' (six feet) from a mechanical air inlet...
  • Page 11: Finishing Around The Fireplace

    We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design, for example: The available European Home Power Vent models are: candles, plastic or pictures. This can cause melting, deformation, discoloration LDVPV47 (Linear, Interior In-line Power Vent, document, XG0700).
  • Page 12: Wiring

    NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. All DV 42 ST Indoor fireplaces may be equipped with optional fan kits for circulating heat into the living space. New technology, to meet consumer and government demands for the wise use of...
  • Page 13: Removing And Installing The Door

    DV 42 ST See-through Gas Fireplace Installation Step 5: Removing and Installing the Doors DV 42 ST Ensure the tool is firmly in the lower end of the slot, as shown, Removing the doors then pull toward you. The doors are removed in a few simple steps. Follow these steps below to remove Caution: The latch springs the horizontal access panel, unlatch the door buckles and, remove the door.
  • Page 14 DV 42 ST Installing the Glass Beads and Optional Fire Media The DV 42 ST fireplace is supplied with glass beads. Optional stone and driftwood fire media are available. Remove the door and trim as shown previously. Follow these instructions to ensure all parts are removed or replaced as required.
  • Page 15: Lighting Instructions

    DV 42 ST See-through Gas Fireplace Operation - Model DV 42 ST DV 42 ST with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 16 DV 42 ST See-through Gas Fireplace Operation - Model DV 42 ST E DV 42 ST E with Proflame SIT Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 17: Operation

    • A visual check of the entire vent system and termination. The DV 42 ST is equipped with an adjustable burner, allowing you to raise or lower • An inspection of the explosion relief flappers and the door gasketing to the flames.
  • Page 18: Troubleshooting

    DV 42 ST See-through Gas Fireplace Maintenance Gas Control Valve Troubleshooting DV 42 ST The following is a troubleshooting chart of possible problems: Power Generator PROBLEM CORRECTIVE ACTION Pilot Adjustment Screw Noisy Pilot Flame Locate pilot adjustment screw on gas control valve. Flame is decreased by turn- Wall Switch ing adjustment screw clockwise.
  • Page 19: Spare Parts

    DV 42 ST See-through Gas Fireplace Maintenance Troubleshooting DV 42 ST E DV 42 ST Spare Parts Follow this information to reset the SIT System: 1. Locate the lead to the battery backup, (remove) DV 42 ST DV 42 ST E...
  • Page 20: Warranty

    Company negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this European Home Gas Appliance is limited to the duration of the foregoing warranty.
  • Page 21: Termination Locations

    DV 42 ST See-through Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 (2.1 m) minimum] inches (41 cm) minimum] P = c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y...
  • Page 22 DV 42 ST See-through Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:...
  • Page 23 NOTES...
  • Page 24 EUROPEAN HOME a division of Europa Ja, Inc. 376 Washington St. Suite 203 Malden, MA 02148 tel: 781/324-8383 fax: 781/324-8384 www.europeanhome.com...

Table of Contents